115
Parameter
Select/Display
Factory setting Suggested Setting
Remark
Heat curve
0.10 – 4.00
1.20/0.60
See heat curve graph
below. Will need to
know the design flow
temperature of the
installation at a given
outdoor temperature
to set accurately
Guidance only. 1.0 – 1.5 for rads.
0.6 – 1.0 for Under floor heating
(UFH)
Min. target flow
temp.
15 – 90 °C
15 °C
15°C for Rads. 20°C
for UFH
Max. target flow
temp.
15 – 90 °C
55 °C
55°C or max of
highest required temp
for circuit. i.e. if UFH
mixers need 45°C
then adjust down
accordingly.
55 °C = Heat pump and/or mixed
circuit
Set-back mode
- Eco
- Normal
Eco
Normal
Operating behaviour of the heating
circuits outside the programmed
time periods
Room temp. mod.
- Inactive
- Active
- Expanded
Inactive
Expanded
- Active = The actual room
temperature and room air humidity
are incorporated into the control
- Expanded = In addition to the
effects of the “Active” setting, the
thermostat function is activated
Cooling possible
- No
- Yes
No
No, unless cooling
coding resistor has
been fitted and
installation designed
for cooling
Dew point
monitoring
- No
- Yes
Yes
Yes if doing cooling
Min. cooling targ.
flow temp.
7 – 24 °C
20 °C
20°C
Dew point offset
-10–10 K
2K
2K
Zone 1-9
Parameter
Select/Display
Factory setting Suggested Setting
Remark
Zone activated
- No
- Yes
Yes
Yes
Zone assignment
- No assignmt
- Control
- Rem. contr. 1
- Rem. contr. 2
- Rem. contr. 3
- Rem. contr. 4
Control is
sensocomfort.
Rem. Control is a
VR92
If there is no Vaillant
controller used for the
zone then select no
assignment.
Definds which controller is being
used for the relevent heating zone.
VR92 are addressed in their own
installer menu.
Domestic Hot Water
Parameter
Select/Display
Factory setting Suggested Setting
Remark
Cylinder
- Inactive
- Active
Active
Active
If no DHW on system then select
inactive
Anti-legio. day
- Off
- Monday
- Tuesday
- Wednesday
- Thursday
- Friday
- Saturday
- Sunday
- Daily
Off
Select a day of the
week