Appendix
22
Operating and installation instructions
sensoHOME
0020298974_00
A.2 Maintenance messages
#
Message
Description
Maintenance work
Interval
1
Water defi-
ciency: Fol-
low the in-
structions
in the heat
gen.
The water pressure is
too low in the heating
installation.
Refer to the operat-
ing instructions for the
relevant heat gener-
ator for information on
filling with water
See the operating
instructions for the
heat generator
B
-- Troubleshooting, maintenance message
B.1 Troubleshooting
Symptom
Possible cause
Measure
Display remains dark
The batteries are flat
▶
Change all the batteries. (
→
Page 17)
The product is defect-
ive
▶
Replace the product.
No changes in the
display can be made
via the control ele-
ments
Software error
1. Take all the batteries out.
2. Insert the batteries in the battery compart-
ment, making sure that the poles are the
right way round.
The product is defect-
ive
▶
Replace the product.
It is not possible to
switch to the installer
level
You do not know the
code for the installer
level
▶
Reset the control to the factory settings. All
set values will be lost.
B.2 Troubleshooting
Message
Possible cause
Measure
Heat generator 1 com-
munication interrupted
The cable is defective
▶
Replace the cable.
Incorrect plug connec-
tion
▶
Check the plug connection.
Remote control 1
communication inter-
rupted
The batteries in the
radio remote control
are flat
▶
Replace all of the batteries (
→
Operating
and installation instructions for the radio
remote control).
Room temp. sensor
signal on control in-
valid
Room temperature
sensor defective
▶
Replace the control.