2 Product description
12
Operating and installation instructions
sensoHOME
0020298974_00
MENU
→
SETTINGS
→
Installer level
→
Installation configuration
→
Max. target flow temperat-
ure:°C
Enter the upper limit for the target flow temperature. The
control compares the set value with the calculated target
flow temperature, and regulates to the smaller of these val-
ues.
→
Set-back mode:
→
Eco
The heating function is switched off and the
frost protection function is activated.
At outdoor temperatures that are below
4 °C for longer than four hours, the control
switches the heat generator on and regulates
to the
Set-back temperature: °C
. At an
outdoor temperature above 4 °C, the control
switches the heat generator off. The monit-
oring of the outdoor temperature remains
active.
Heating circuit behaviour outside of the time
periods. Prerequisite:
–
Time-contr.
is activated in the
Heating
→
Mode:
function.
–
Active
or
Inactive
is activated in the
Room temp. mod.:
function.
If
Expanded
is activated in the
Room temp.
mod.:
, the control regulates to the target
room temperature 5 °C independently of the
outdoor temperature.
→
Normal
The heating function is switched on. The con-
trol regulates to the
Set-back temperature:
°C
.
Prerequisite:
–
Time-contr.
is activated in the
Heating
→
Mode:
function.
The behaviour can be adjusted separately for each heating circuit.
→
Room temp. mod.:
→
Inactive
→
Active
Adjusting the flow temperature based on the
current room temperature.
→
Expan-
ded
Adjusting the flow temperature based on the
current room temperature. The control also
activates/deactivates the zone.
–
The zone is deactivated: Current room
tempe 2/16 K > set room temper-
ature
–
Zone is activated: Current room temperat-
ure < set room temperature - 3/16 K