Product description 2
0020298974_00
sensoHOME
Operating and installation instructions
13
MENU
→
SETTINGS
→
Installer level
→
Installation configuration
The installed temperature sensor measures the current room temperature. The control calcu-
lates a new target room temperature that is used to adjust the flow temperature.
–
Difference = Set target room temperature - current room temperature
–
New target room temperature = Set target room tempe difference
Prerequisite: In the
Zone assignment:
function, the control and/or the remote control is as-
signed to the zone in which the control or remote control is installed.
The
Room temp. mod.:
function is ineffective if
No assignmt
is activated in the
Zone as-
signment:
function.
→
Control type:
2-point
Corresponds to an on/off control system
Analog.
Corresponds to a modulating control system
→
Zone
→
Zone activated:
Deactivate zones that are not required. All existing zones
appear in the display.
→
Zone assignment:
Assign the control to the selected zone. The control must
be installed in the selected zone. The control system also
uses the room temperature sensor for the assigned unit.
The
Room temp. mod.:
function is ineffective if you have
not assigned a zone to the control.
→
Zone valve status:
→
Domestic hot water
→
Cylinder:
If there is an existing domestic hot water cylinder, the
Act-
ive
setting must be selected.
→
Target flow temperature: °C
→
Circulation pump:
→
Anti-legio. day:
Define the days on which you want the anti-legionella func-
tion to run. On these days, the water temperature is in-
creased to above 60 °C. The circulation pump is activated.
The function ends after 120 minutes at the latest.
If the
Absence
function is activated, the anti-legionella
function is not carried out. As soon as the
Absence
func-
tion ends, the anti-legionella function is carried out.
→
Anti-legio. time:
Define the time at which you want the anti-legionella func-
tion to run.
→
Radio link
→
Control reception strength:
Read the reception strength between the radio receiver unit
and outdoor temperature sensor.
–
4: The radio link is within the acceptable range. If the
reception strength is < 4, the radio link is not stable.
–
10: The radio link is highly stable.
→
OT sensor reception
strength:
Read the reception strength between the radio receiver unit
and outdoor temperature sensor.
–
4: The radio link is within the acceptable range. If the
reception strength is < 4, the radio link is not stable.
–
10: The radio link is highly stable.
→
Screed drying profile
Setting target flow temperature per day in accordance with
the construction regulations