background image

Product description 4

0020213396_00 flexoTHERM Operating instructions

11

Sym-
bol

Meaning

Explanation

Heating mode

Continuously
on: Heating
mode active

Cooling mode

Continuously
on: Cooling
mode active
(active or
passive)

Hot water gener-
ation

Continuously
on: Hot water
handling mode
active

F.XXX

Fault in the
product

Appears in-
stead of the
basic display,
may be an ex-
planatory plain
text display

The basic display shows you the product's
operating mode. If you press a selection
button, the activated function is displayed
in the display.
You can switch back to the basic display
by:

Pressing

to exit the selection levels

Not pressing any button for longer than
15 minutes.

If there is a fault message present, the ba-
sic display switches to the fault message.

4.8 Operating concept

Op-
erator
control
element

Function

Displaying the environmental
energy yield in heating mode,
hot water handling mode and
cooling mode

Cancelling a change to a set
value

Going one selection level
higher

Op-
erator
control
element

Function

Confirm setting

Going one selection level lower

+

at the
same
time

Calling up the menu

or

Reducing or increasing the set
value

Scrolling through menu entries

The current function of the

and

selec-

tion buttons is shown on the display.
Adjustable values are always displayed as
flashing.
You must always confirm a change to a
value. Only then is the new setting saved.
You can press

to cancel a procedure at

any time.

4.9 Menu display

Xxxx

Xxxxxxxxxxx

Xxxx Xxxxxxx

Xxxxxxxxxx

xxxxxx

Xxxxxxx

1

4

3

2

1

Scroll bar

2

Current assign-
ment of the se-
lection buttons

3

Selection level
list entries

4

Selection level

You can find an overview of the menu
structure in the appendix.

Содержание flexoTHERM VWF 5x

Страница 1: ...erating instructions flexoTHERM VWF 5x 19x 4 GB IE Operating instructions Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 28 10 info vaillant...

Страница 2: ...4 9 Menu display 11 4 10 Operating levels 12 5 Operating 12 5 1 Starting up the product 12 5 2 Adjusting the target cylinder temperature 12 5 3 Yield indicator 12 5 4 Displaying the Live Monitor 12 5...

Страница 3: ...ended exclus ively for domestic use The system is intended as a heat generator with cooling function for closed central heat ing installations and for hot wa ter generation Operation of the pump outsi...

Страница 4: ...ocuments particu larly the Safety section and the warnings 1 2 3 Risk of death due to explosive and flammable materials Do not use or store explosive or flammable materials e g petrol paper paint in t...

Страница 5: ...t at all Never attempt to carry out maintenance work or repairs on your product yourself Faults and damage should be immediately rectified by a competent person Adhere to the maintenance intervals spe...

Страница 6: ...ons Ensure that only officially cer tified competent persons with appropriate protective equip ment carry out maintenance work on the refrigerant circuit or access it Arrange for the refriger ant that...

Страница 7: ...se 2 3 Applicability of the instructions These instructions apply only to Applicability Great Britain OR Ireland Product VWF 57 4 VWF 87 4 VWF 117 4 VWF 157 4 VWF 197 4 Applicability Great Britain OR...

Страница 8: ...emperat ure drops below a certain value The outlet temperature of the heat source is constantly measured If the outlet tem perature of the heat source falls below a certain value the compressor tempor...

Страница 9: ...equirement without switching off prematurely 60 minutes of uninterrupted operation 4 2 8 Safety cut out SCO in the heating circuit If the temperature in the heating circuit of the internal auxiliary e...

Страница 10: ...pump 9 Display 4 7 Basic display 50 d kWh Sym bol Meaning Explanation Compressor Filled Com pressor in op eration Not filled Compressor not in operation bar Current filling pressure of the heating sy...

Страница 11: ...fault message 4 8 Operating concept Op erator control element Function Displaying the environmental energy yield in heating mode hot water handling mode and cooling mode Cancelling a change to a set...

Страница 12: ...ating hot water generation and cooling modes Displays the working figure for a period of a month and the total for the heating and hot water generation modes The work ing figure is the ratio of therma...

Страница 13: ...hlorine Clean the casing with a damp cloth and a little solvent free soap 6 1 3 Checking the system pressure Check the filling pressure of the heating installation every day for a week after initial s...

Страница 14: ...s that are hazardous to human health and the envir onment In this case dispose of the batteries at a collection point for batteries 8 3 1 Arranging disposal of the brine fluid The product is filled wi...

Страница 15: ...r antee details of which can be found on the registration card included with this appli ance In order to qualify for guarantee after one year the appliance must be serviced in accordance with our inst...

Страница 16: ...h Working figure Total Heating Cumulative value Energy yield Month Domestic hot water Cumulative value kWh Working figure Month Domestic hot water Cumulative value Energy yield Total Domestic hot wate...

Страница 17: ...g rod power Current value kW Information Contact data Phone number Serial number Permanent value Operating hours total Cumulative value h Hours heating Cumulative value h DHW operating hours Cumulativ...

Страница 18: ......

Страница 19: ......

Страница 20: ...les 02 07 022 09 28 Vaillant Service Solutions 03 30 100 31 43 Spares Technical Enquiries 017 73 59 66 15 info vaillant co uk technicalspares groupservice co uk www vaillant co uk These instructions o...

Отзывы: