4 Set-up
6
Installation and maintenance instructions eloSTOR pro 0020196671_06
4.2
Requirements for the installation site
▶
Observe the following requirements:
–
Installation height above sea level: < 2000 m
–
Installation only in rooms that are always dry and free
of frost
–
Installation only on a level, vertical and stable wall
–
Installation only on a wall with sufficient load-bearing
capacity for the filled product (
→
Appendix: Technical
data)
4.3
Observing the minimum clearances
≥500
▶
Comply with the minimum clearances during installation.
4.4
Installing the product
Note
All VEH/7 cylinders can be installed with the exist-
ing safety group.
A1
A2
220 - 305
240
100
R ½
R ½
350
100
R1
6
1
2
3
5
4
1
Product bracket (re-
placement for VEH 5)
2
Product bracket (new
installation or replace-
ment for VEH 6)
3
Bearing surfaces for
wall support
4
Hot water connection
5
Discharge connection
6
Cold water connection
A1
Distance between the
product bracket and
water connections
(replacement for VEH 5)
A2
Distance between the
product bracket and
water connections
(new installation or
replacement for VEH 6)
1.
Install the product bracket.
Unit
A1
(Replace-
ment for
VEH 5)
A2
(New
installation
or
replacement
for VEH 6)
VEH 50/7-3
mm
790
690
VEH 80/7-3
mm
1020
920
VEH 100/7-3
mm
1020
920
VEH 120/7-3
mm
1020
920
2.
Hang the product in the product bracket.
–
Lateral corrections are possible as a result of move-
ment.
3.
Install the safety group to the water connections of the
VEH
.
Conditions
: New safety group required
–
Vaillant
Safety group without a pressure reducer
0020174068
–
Vaillant
Safety group with a pressure reducer
0020174067
Conditions
:
VEH 80
▶
Replace the connectors from the safety group with the
connectors supplied for the
VEH 80
.