Gas installation
5
Gas installation
The work described in this section must only be carried out
by a competent person.
5.1
Preparing for installation
a
Danger!
Risk of death from incorrectly installed
gas system!
An incorrect gas installation can result in
leaks and an explosion.
>
During installation, the legal directives
and the local regulations for gas supply
companies must be observed.
a
Danger!
Risk of death from incorrectly installed
gas system!
Tension in the gas line can result in leaks or
an explosion.
>
Make sure there are no stresses in the
gas lines when it is installed.
b
Caution.
Risk of damage caused by incorrect gas
installation.
Excess test pressure or operating pressure
can cause damage to the gas valve.
>
When the entire gas installation is tested
for leaks, the maximum pressure at the
gas valve must not exceed 0.75 kPa
(75 mbar).
b
Caution.
Risk of damage caused by contaminated
lines.
Foreign bodies such as welding remnants,
sealing residue or dirt in the supply lines
for gas can cause damage to the boiler.
>
Blow the gas line clean prior to installa-
tion.
b
Caution.
Risk of damage caused by using the
wrong gas type.
Using the wrong gas type can cause a fault
shutdown on the boiler. Furthermore, igni-
tion and combustion noise may occur in the
boiler.
>
Only use propane gas for propane-fired
boilers in accordance with BS 4250: Part
1 (1987).
5.2
Connecting the gas pipe
2
6
7
3
5
4
1
5.1 Fitting the gas connection
>
Make the gas connection as shown.