background image

12

Operating instructions ecoTEC pro 0020209590_03

Appendix
A

Status codes

Overview

Status codes that are not listed here can be viewed in the installation instructions.

Status code

Parameter

Meaning

Displays in heating mode

S.00

Heating: No heat demand

Heating: No heat demand

S.02

Heating mode: Pump pre-run

Heating mode: Pump pre-run

S.03

Heating mode: Ignition

Heating mode: Ignition

S.04

Heating mode: Burner on

Heating mode: Burner on

S.06

Heating mode: Fan overrun

Heating mode: Fan overrun

S.07

Heating mode: Pump overrun

Heating mode: Pump overrun

S.08

Heating mode: Anti-cycling time

Heating, remaining anti-cycling time xx mins

Displays in hot water handling mode

S.10

DHW demand

Hot water requirement via flow sensor

S.14

DHW mode: Burner on

DHW mode: Burner on

Displays in Comfort mode with warm start or hot water handling mode with cylinder

S.20

DHW demand

Hot water requirement

S.22

DHW mode: Pump pre-run

DHW mode: Pump pre-run

S.24

DHW mode: Burner on

DHW mode: Burner on

Others

S.31

No heat demand: Summer mode

Summer mode active

S.34

Heating mode: Frost protection

Frost protection mode, frost protection

S.46

Waiting time: Measuring program

Comfort protection mode, flame loss at minimum load

B

Troubleshooting

Fault

Cause

Measure

Product does not start
up:

No hot water

Heating remains cold

The gas isolator cock installed on-site and/or the gas
isolator cock on the product is closed.

Open both gas isolator cocks.

The power supply in the building is disconnected.

Check the fuse in the building. The product
switches on automatically when the power is
restored.

The product is switched off.

Switch on the product (

"Switching on the

product" section).

The heating flow temperature is set too low or to the

Heating off

position, and/or the hot water temperature

is set too low.

Set the heating flow temperature and hot water
temperature (

"Setting the heating flow temper-

ature" section/

"Setting the hot water temperat-

ure" section).

The system pressure is insufficient.
Low water pressure in the heating installation (fault mes-
sage:

F.22

).

Fill the heating installation (

"Filling the heating

installation" section).

There is air in the heating installation.

Have your competent person purge the heating
installation.

After three unsuccessful attempts to ignite the flame, the
product switches to fault mode (fault message:

F.28

).

Press the fault clearance key for one second.
The product makes another attempt to ignite the
flame.
If you have been unable to eliminate the ignition
fault after three fault clearance attempts, consult
a competent person.

Hot water generation
functioning correctly;
heating does not start
up.

The external controller is not set correctly.

Set the external controller correctly (

Controller

operating instructions).

Содержание ecoTEC pro 30 H combi A VUW 306/5-3

Страница 1: ...en Operating instructions ecoTEC pro VUW 6 5 3 0020209590_03 29 07 2020 ...

Страница 2: ...arting up the product 8 4 7 Switching on the product 8 4 8 Setting the heating flow temperature 8 4 9 Setting the hot water temperature 8 4 10 Switching the comfort mode on and off 8 4 11 Switching off the product s functions 8 4 12 Guaranteeing the correct filling pressure of the heating installation 9 4 13 Protecting the heating installation against frost 9 5 Troubleshooting 9 5 1 Detecting and ...

Страница 3: ...hildren unless they are supervised Any other use that is not specified in these instructions or use beyond that specified in this document shall be considered improper use Any direct commercial or industrial use is also deemed to be improper Caution Improper use of any kind is prohibited 1 3 General safety information 1 3 1 Installation by competent persons only The installation inspection mainten...

Страница 4: ...ain pipework to constructional conditions that may affect the operational reliability of the product 1 3 7 Risk of corrosion damage due to unsuitable combustion and room air Sprays solvents chlorinated cleaning agents paint adhesives ammonia com pounds dust or similar substances may lead to corrosion on the product and in the air flue pipe Ensure that the combustion air supply is always free of fl...

Страница 5: ...ription 3 1 Product design 1 2 1 Control elements 2 Plate with serial number on the rear 3 2 Control elements 50 1 2 3 4 5 1 On off button 2 Built in controller ac cessory 3 Fault clearance button 4 Operating buttons 5 Display 3 2 1 Operator control panel 50 1 2 3 4 8 7 5 6 1 Current heating flow temperature filling pressure of the heating installation operating mode fault code or additional infor...

Страница 6: ...ure Week year Cat Permissible gas categories Types Approved gas fired units PMS Permissible total overpressure in heating mode PMW Permissible total overpressure during hot water generation Tmax Max flow temperature Information on the identification plate Meaning ED 92 42 Current efficiency directive fulfilled with 4 rating V Hz Mains voltage and mains frequency W Max electrical power consumption ...

Страница 7: ...the comfort mode Activating the operating mode Confirm the set value Going one selection level lower at the same time Calling up the menu or Reducing or increasing the set value Scrolling through menu entries The current function of the and buttons is shown in the display Adjustable values are always displayed as flashing You must always confirm a change to a value Only then is the new setting sav...

Страница 8: ...g the competent person first 1 Press The set hot water temperature flashes in the display Condition No controller connected Change the hot water temperature by pressing or Confirm by pressing Condition Controller connected Use to set the maximum possible hot water temper ature on the product Confirm by pressing Set the required hot water temperature on the controller Controller operating instructi...

Страница 9: ...heating water 1 Ask a competent person where the filling cock is loc ated 2 Connect the filling tap to a heating water supply in the way you were told by the competent person 3 Open all radiator valves thermostatic radiator valves of the heating installation 4 Open the heating water supply 5 Turn the filling cock on slowly and allow water to flow in until the required filling pressure has been rea...

Страница 10: ... the gas stopcock is open Temporarily decommission the product only if no frost is expected Temporarily decommission the product only if no frost is expected Press the on off button The display goes out When decommissioning the product for a prolonged period e g holiday close the gas isolator cock and also for combination products the cold water stop valve 7 2 Permanently decommissioning the produ...

Страница 11: ...g instructions 11 9 2 Customer service To ensure regular servicing it is strongly recommended that arrangements are made for a Maintenance Agreement Please contact Vaillant Service Solutions for further details Telephone 0330 100 3461 ...

Страница 12: ...rt up No hot water Heating remains cold The gas isolator cock installed on site and or the gas isolator cock on the product is closed Open both gas isolator cocks The power supply in the building is disconnected Check the fuse in the building The product switches on automatically when the power is restored The product is switched off Switch on the product Switching on the product section The heati...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...blisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 492191 18 0 Fax 492191 18 2810 info vaillant de www vaillant de These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer s written consent Subject to technical modifications 0020209590_03 ...

Отзывы: