background image

0020209590_03 ecoTEC pro Operating instructions

9

4.12

Guaranteeing the correct filling pressure of
the heating installation

4.12.1 Checking the filling pressure of the heating

installation

Note

To ensure that the heating installation operates
smoothly, the filling pressure when the heating
installation is cold must be between 0.10 MPa and
0.20 MPa (1.0 bar and 2.0 bar) or lie between the
two dashed lines in the bar graph display.

If the heating installation extends over several
storeys, a higher filling pressure may be required
for the heating installation. Ask a competent per-
son for details.

In addition, the

symbol appears after approx.

one minute.

If the filling pressure in the heating installation
falls below 0.05 MPa (0.5 bar), then the product
switches off. The display alternates between the
fault message

F.22

and the current filling pres-

sure.

1.

Press

twice.

The values for the current filling pressure and for the
minimum and maximum filling pressures appear in
the display.

2.

Check the filling pressure in the display.

Result 1:

System pressure: 0.10 to 0.20 MPa (1.00 to 2.00 bar)
The filling pressure is in the intended pressure range.

Result 2:

Filling pressure: < 0.08 MPa (< 0.80 bar)

Fill the heating installation. (

Page 9)

If you have topped up the installation with suf-
ficient heating water, the display automatically
disappears after 20 seconds.

4.12.2 Filling the heating installation

Caution.
Risk of material damage due to heating
water that is extremely calciferous or cor-
rosive or contaminated by chemicals.

Unsuitable tap water damages the seals
and diaphragms, blocks components in the
product and heating installation through
which the water flows and causes noise.

Only fill the heating installation with suit-
able heating water.

1.

Ask a competent person where the filling cock is loc-
ated.

2.

Connect the filling tap to a heating water supply in the
way you were told by the competent person.

3.

Open all radiator valves (thermostatic radiator valves) of
the heating installation.

4.

Open the heating water supply.

5.

Turn the filling cock on slowly and allow water to flow in
until the required filling pressure has been reached.

6.

Close the heating water supply.

7.

Purge all radiators.

8.

Check the filling pressure in the display.

9.

Top up with more water if necessary.

10. Close the filling cock.
11. Return to the basic display. (

Page 7)

4.13

Protecting the heating installation against
frost

4.13.1 Frost protection function

Caution.
Risk of material damage due to frost.

The frost protection function cannot guaran-
tee flow through the entire heating installa-
tion, which means that parts of the heating in-
stallation may freeze and therefore become
damaged.

During a period of frost, ensure that the
heating installation remains in operation
and that all rooms are sufficiently heated,
even when you are away.

Note

To keep the frost protection devices active, you
should switch your product on and off using the
control, if one is installed.

If the heating flow temperature falls below 5 °C when the
on/off button is on, the product starts up and heats the cir-
culating water to approx. 30 °C on both the heating side and
the domestic hot water side (if available).

4.13.2 Draining the heating installation

When the unit is switched off for an extended period, frost
protection can be guaranteed by completely draining the
heating installation and the product.

Consult a competent person about this.

5

Troubleshooting

5.1

Detecting and rectifying faults

If faults occur, proceed in accordance with the table in
the appendix.
Troubleshooting (

Page 12)

If the fault cannot be eliminated using the specified
measures or if fault messages (

F.xx

) occur, contact a

competent person.

Содержание ecoTEC pro 30 H combi A VUW 306/5-3

Страница 1: ...en Operating instructions ecoTEC pro VUW 6 5 3 0020209590_03 29 07 2020 ...

Страница 2: ...arting up the product 8 4 7 Switching on the product 8 4 8 Setting the heating flow temperature 8 4 9 Setting the hot water temperature 8 4 10 Switching the comfort mode on and off 8 4 11 Switching off the product s functions 8 4 12 Guaranteeing the correct filling pressure of the heating installation 9 4 13 Protecting the heating installation against frost 9 5 Troubleshooting 9 5 1 Detecting and ...

Страница 3: ...hildren unless they are supervised Any other use that is not specified in these instructions or use beyond that specified in this document shall be considered improper use Any direct commercial or industrial use is also deemed to be improper Caution Improper use of any kind is prohibited 1 3 General safety information 1 3 1 Installation by competent persons only The installation inspection mainten...

Страница 4: ...ain pipework to constructional conditions that may affect the operational reliability of the product 1 3 7 Risk of corrosion damage due to unsuitable combustion and room air Sprays solvents chlorinated cleaning agents paint adhesives ammonia com pounds dust or similar substances may lead to corrosion on the product and in the air flue pipe Ensure that the combustion air supply is always free of fl...

Страница 5: ...ription 3 1 Product design 1 2 1 Control elements 2 Plate with serial number on the rear 3 2 Control elements 50 1 2 3 4 5 1 On off button 2 Built in controller ac cessory 3 Fault clearance button 4 Operating buttons 5 Display 3 2 1 Operator control panel 50 1 2 3 4 8 7 5 6 1 Current heating flow temperature filling pressure of the heating installation operating mode fault code or additional infor...

Страница 6: ...ure Week year Cat Permissible gas categories Types Approved gas fired units PMS Permissible total overpressure in heating mode PMW Permissible total overpressure during hot water generation Tmax Max flow temperature Information on the identification plate Meaning ED 92 42 Current efficiency directive fulfilled with 4 rating V Hz Mains voltage and mains frequency W Max electrical power consumption ...

Страница 7: ...the comfort mode Activating the operating mode Confirm the set value Going one selection level lower at the same time Calling up the menu or Reducing or increasing the set value Scrolling through menu entries The current function of the and buttons is shown in the display Adjustable values are always displayed as flashing You must always confirm a change to a value Only then is the new setting sav...

Страница 8: ...g the competent person first 1 Press The set hot water temperature flashes in the display Condition No controller connected Change the hot water temperature by pressing or Confirm by pressing Condition Controller connected Use to set the maximum possible hot water temper ature on the product Confirm by pressing Set the required hot water temperature on the controller Controller operating instructi...

Страница 9: ...heating water 1 Ask a competent person where the filling cock is loc ated 2 Connect the filling tap to a heating water supply in the way you were told by the competent person 3 Open all radiator valves thermostatic radiator valves of the heating installation 4 Open the heating water supply 5 Turn the filling cock on slowly and allow water to flow in until the required filling pressure has been rea...

Страница 10: ... the gas stopcock is open Temporarily decommission the product only if no frost is expected Temporarily decommission the product only if no frost is expected Press the on off button The display goes out When decommissioning the product for a prolonged period e g holiday close the gas isolator cock and also for combination products the cold water stop valve 7 2 Permanently decommissioning the produ...

Страница 11: ...g instructions 11 9 2 Customer service To ensure regular servicing it is strongly recommended that arrangements are made for a Maintenance Agreement Please contact Vaillant Service Solutions for further details Telephone 0330 100 3461 ...

Страница 12: ...rt up No hot water Heating remains cold The gas isolator cock installed on site and or the gas isolator cock on the product is closed Open both gas isolator cocks The power supply in the building is disconnected Check the fuse in the building The product switches on automatically when the power is restored The product is switched off Switch on the product Switching on the product section The heati...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...blisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 492191 18 0 Fax 492191 18 2810 info vaillant de www vaillant de These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer s written consent Subject to technical modifications 0020209590_03 ...

Отзывы: