Supplied By www.heating spares.co Tel. 0161 620 6677
13
Instructions for use ecoTEC
4.8.1 Problems due to low system water pressure
The device switches to “
Fault
” if the water pressure in
the heating system is too low. This malfunction is indi-
cated by the fault code “
F.22
” (dry fire) or “
F.23
” or
“
F.24
” (lack of water).
You can only start up the appliance again when the
heating system is sufficiently filled with water.
4.8.2 Ignition problems
bar
i
F
P
plus
pro
3
2
1
Fig. 4.17 Troubleshooting
If the burner fails to ignite after five attempts, the
device does not start up and switches to “
Fault
”. This is
indicated by the fault code “
F.28
” or “
F.29
” in the dis-
play. On ecoTEC plus appliances the display also shows
the flame symbol with a cross through it (
1
). On ecoTEC
pro appliances, the red LED (
2
) also lights up.
Automatic ignition can only take place after you manual-
ly reset the fault.
• To reset the fault, press the reset button (
3
) and hold
it down for one second.
Caution
If the boiler still shuts off after three attempts
of resetting, please consult your installer or
Vaillant Service Solutions.
4.8.3 Flue problems
The appliances are fitted with a fan. If the fan does not
work properly, the appliance will switch itself off.
The display shows the symbols and and the fault
message “
F.32
”.
Note
If contacting Vaillant Service Solutions please
remember to quote the fault code, as this will
help to pinpoint the fault.
4.9
Turning off the boiler
bar
i
F
P
1
Fig. 4.18 Switching off the appliance
• Turn the main ON/OFF control (
1
) to the „0“ position.
Caution
The boiler frost protection and monitoring sys-
tems are only active when the main ON/OFF
control of the appliance is in the “I” position
and it is not disconnected from the main power
supply.
To ensure that these protection devices remain active,
switch your boiler on and off using the external control-
ler.
Note
If the appliance is switched off for a long time
(for example when you are on holiday) you
should also turn off the gas supply, the cold
water service valve and the electrical supply.
Note
Do not turn the ecoTEC system boilers OFF if a
hot water cylinder is also incorporated in the
system unless there is no demand for domestic
hot water.
Operation 4
Содержание ecoTEC plus 612
Страница 54: ...Supplied By www heating spares co Tel 0161 620 6677...
Страница 55: ...Supplied By www heating spares co Tel 0161 620 6677...
Страница 56: ...Supplied By www heating spares co Tel 0161 620 6677 839592_05 GB 08 2006...
Страница 58: ...Supplied By www heating spares co Tel 0161 620 6677 834449_09GB_082006 qxd 10 08 2006 12 20 Seite 2...
Страница 92: ...Supplied By www heating spares co Tel 0161 620 6677 36 834449_09GB_082006 qxd 10 08 2006 12 20 Seite 36...
Страница 116: ...Supplied By www heating spares co Tel 0161 620 6677 60 834449_09GB_082006 qxd 10 08 2006 12 20 Seite 60...
Страница 117: ...Supplied By www heating spares co Tel 0161 620 6677 61 834449_09GB_082006 qxd 10 08 2006 12 20 Seite 61...
Страница 118: ...Supplied By www heating spares co Tel 0161 620 6677 62 834449_09GB_082006 qxd 10 08 2006 12 20 Seite 62...
Страница 119: ...Supplied By www heating spares co Tel 0161 620 6677 63 834449_09GB_082006 qxd 10 08 2006 12 20 Seite 63...
Страница 120: ...Supplied By www heating spares co Tel 0161 620 6677 834449_09 GB 082006 834449_09GB_082006 qxd 10 08 2006 12 20 Seite 64...
Страница 122: ...Supplied By www heating spares co Tel 0161 620 6677...
Страница 124: ...Supplied By www heating spares co Tel 0161 620 6677 0020010870 01 GB 03 2006 2...
Страница 142: ...Supplied By www heating spares co Tel 0161 620 6677 0020010870 01 GB 03 2006 20...
Страница 162: ...Supplied By www heating spares co Tel 0161 620 6677 Notes 0020010870 01 GB 03 2006 40...
Страница 163: ...Supplied By www heating spares co Tel 0161 620 6677...
Страница 179: ...Supplied By www heating spares co Tel 0161 620 6677 15 Instructions for use ecoTEC...
Страница 180: ...Supplied By www heating spares co Tel 0161 620 6677 16 Instructions for use ecoTEC...
Страница 181: ...Supplied By www heating spares co Tel 0161 620 6677 20 C 20 C 15 C 5 C bar bar VRT VRC i F P...
Страница 182: ...Supplied By www heating spares co Tel 0161 620 6677...
Страница 183: ...Supplied By www heating spares co Tel 0161 620 6677 19 Instructions for use ecoTEC...
Страница 184: ...Supplied By www heating spares co Tel 0161 620 6677 838402_04 GB 08 2006...