38
Installation and maintenance instructions ecoFIT pure 0020230531_06
13.5.8 Replacing the expansion relief valve
1
2
1.
Remove the clip
(2)
.
2.
Remove the expansion relief valve.
3.
Fit the new expansion relief valve with a new O-ring.
4.
Reattach the clip
(2)
.
13.5.9 Replacing the volume flow sensor
1
B
A
1.
Pull out the plug.
2.
Remove the volume flow sensor
(1)
.
3.
Install the new volume flow sensor.
4.
Plug in the plug.
13.5.10 Replace the pressure sensor
1
2
1.
Pull out the plug.
2.
Remove the clip
(1)
.
3.
Remove the pressure sensor
(2)
.
4.
Install the new pressure sensor.
5.
Reattach the clip
(1)
.
13.6
Checking the product for leak-tightness
▶
Check that the product is leak-tight. (
14 Decommissioning the product
▶
Switch off the product.
▶
Disconnect the product from the electrical installation.
▶
Close the gas stopcock.
▶
Close the cold-water isolation valve.
▶
Drain the product. (
15 Recycling and disposal
Disposing of the packaging
▶
Dispose of the packaging correctly.
▶
Observe all relevant regulations.
▶
For detailed information refer to www.vaillant.co.uk.