0020230531_06 ecoFIT pure Installation and maintenance instructions
11
6
Set-up
6.1
Checking the scope of delivery
▶
Check that the scope of delivery is complete and intact.
Number
Designation
1
Heat generator
1
Unit mounting bracket
1
Flexible condensate discharge pipe
6
3/4" seals
4
1/2" seals
1
Service valve
1
Gas stopcock
1
Filling loop
2
Connection pipe (heating flow and return)
1
Cold water connection pipe
1
Domestic hot water connection pipe
1
Gas pipe
1
Drain pipe for the Pressure relief valve
1
Mounting template
1
Enclosed documentation
6.2
Dimensions
96
121
34
123
185
390
123
58 58
220
700
150
295
150
76
1
2
3
4
5
7
6
1
Heating flow
2
Domestic hot water
connection
3
Gas connection
4
Cold water connection
5
Heating return
6
Rear air/flue connection
7
Top air/flue connection