Set-up 4
0020077989_04 auroTHERM exclusive Installation and maintenance instructions
23
Condition
: Fastening type: To rafters
1
2
▶
Define the clearances of the roof anchors. (
→
Page 14)
▶
Expose the rafters at the corresponding position
(1)
.
▶
Position the roof anchor
(2)
. Ensure the correct position
of the top, middle and lower roof anchors.
3
4
▶
Undo the top bolt until the height of the roof anchor can
be adjusted
(3)
.
–
Working materials: SW 13 spanner
▶
Adjust the roof anchor to the height of the pantiles, so
that the top part of the roof anchor lies on the roofing
(4)
.
▶
Tighten the top bolt.
–
Working materials: SW 13 spanner
5
6
A
B
▶
Screw the roof anchor onto the rafters using the three
bolts supplied
(5)
.
▶
Slide the pantiles into their original position again
(6)
.
▶
To ensure that the tiles lie tightly together, notch gutter-
ing onto the underside
(A)
or the upper side
(B)
of the
pantile using a hammer, if necessary.
Note
For some roof types, it may be necessary to
offset the roof anchor laterally opposite the
rafters.
To do this, use the "long base" accessory (not
available in all countries).
Condition
: Fastening type: To roof batten
1
3
2
▶
Define the clearances of the roof anchors. (
→
Page 14)
▶
Slide one to two pantiles upwards at the corresponding
position above the roof batten
(1)
.
▶
Undo the top bolt until the height of the roof anchor can
be adjusted
(2)
.
–
Working materials: SW 13 spanner
▶
Hang the roof anchor on the roof batten
(3)
. Ensure that
the top, middle and lower roof anchors are positioned
correctly.
4
▶
Adjust the roof anchor to the height of the pantiles, so
that the upper section lies on the roofing and the base is
pushed tight against the roof batten from the bottom
(4)
.
▶
Ensure that the roof anchor fits securely around the roof
batten and pantile when it engages.