Set-up 4
0020077989_04 auroTHERM exclusive Installation and maintenance instructions
21
Vertical collector position
Installation angle 60°
Weights/rack [kg]
L
1
L
2
To secure against sliding and
lifting
To secure only against lifting
(if secured/anchored against
sliding)
Note
If the collectors are also anchored using steel ropes from the installation set
for the storm protection, the reduced weights can only be used to protect
against lifting.
When there are at least two collectors in a row, the ballast loads can be re-
duced by half for the outer rack.
Basic wind speed [km/h]
Store
Building height
Building height
up to 10
m
10-18 m
18-25 m
up to 10
m
10-18 m
18-25 m
up to 72
Coast and islands
L
₁
L
₂
406
372
477
441
522
485
30
246
30
291
35
325
up to 81
Inland
L
₁
L
₂
352
319
460
424
532
494
30
212
30
280
37
325
up to 81
Coast and islands
L
₁
L
₂
516
479
607
566
664
621
35
315
45
372
52
407
up to 90
Inland
L
₁
L
₂
460
424
568
529
641
599
30
280
41
348
49
393
up to 90
Coast and islands
L
₁
L
₂
604
564
713
669
785
739
45
370
58
438
67
483
up to 99
Inland
L
₁
L
₂
568
529
677
634
785
739
41
348
54
415
67
483
up to 99
Coast and islands
L
₁
L
₂
749
704
857
809
930
879
62
461
75
528
84
573
up to 108
Inland
L
₁
L
₂
677
634
821
774
930
879
54
415
71
506
84
573
up to 108
Coast and islands
L
₁
L
₂
893
844
1002
949
1110
1054
80
551
92
619
105
686