3
4
Fig. 6.17 Mounting the hydraulic connections (6 or more collectors)
n
With fields arranged side by side
h
Note
If you connect 6 or more collectors
one after another, the hydraulic con-
nections must be arranged diagonal-
ly, to force a complete flow.
• Insert the return (inlet) (
2
) into the lower
side opening on one side and, diagonally
across it, the supply (outlet with opening
for collector sensor) (
4
) into the upper side
opening.
• Insert the collector sensor into the open-
ing.
• Fix connections and plugs with the clamps.
• Mount the plug without vent (
3
) in the
lower part of the collector.
• Mount the plug with vent (
1
) in the highest
position.
• Connect the collector supply and return to
the system with the connection pipes.
• If necessary check the connections for
leaks.
a
1
2
Fig. 6.18 Collector connection (fields arrangedn top of each other)
u
With fields arranged on top of each
other
• Join the collectors with the pipe coupling.
• Fix the pipe coupling with the clamps.
a
Caution!
Danger of damage to the collector as
a result of incorrect assembly!
Make sure that the clamps (1) slide
into the slot on the pipe coupler (B).
On-roof mounting 6