Installation manual auroTHERM 0020057143_02
24
2
1
a
A
B
Fig. 6.14 Mounting the connectors (field arrangement side by side)
n
With fields arranged side by side
• Insert the hydraulic connectors
up to the
end stop
into the corresponding openings
on the side of the collectors.
• Fix the connectors with the clamps, slide
the clamps for the upper connection in the
rail from the top, and then clamps for the
lower connection from the bottom.
a
Caution!
Danger of damage to the collector as
a result of incorrect assembly!
Make sure that the clamp (A) slides
into the slot on the pipe coupler (B).
2
3
1
a
A
B
Fig. 6.15 Mounting other collectors (field arrangement side by side)
n
With fields arranged side by side
• Place the next collector (
1
) on the lower
mounting rail.
• Slide the collector on the first collector (
2
),
paying attention to the hydraulic connec-
tors.
• Fix the hydraulic connectors inserted into
the opening up to the limit stop with the
clamps (
3
).
• Tighten all remaining clamping elements of
the roof anchors.
a
Caution!
Danger of damage to the collector as
a result of incorrect assembly!
Make sure that the clamp (A) slides
into the slot on the pipe coupler (B).
1
2
3
4
Fig. 6.16 Mounting the hydraulic connections (1 - 5 collectors)
n
With fields arranged side by side
• Connect the supply (outlet with opening
for collector sensor) (
1
) on top.
• Insert the collector sensor into the open-
ing.
• Connect the return (inlet) (
2
) at the bot-
tom.
• Mount the plug without vent (
3
) in the
lower part of the collector.
• Mount the plug with vent (
4
) in the highest
position.
• Fix connections and plugs with the clamps.
• Connect the collector supply and return to
the system with the connection pipes.
• If necessary check the connections for
leaks.
6 On-roof mounting