background image

 

 

 

 

 

 

 

 

 

Prism Lite Series Touch Panel 

User Manual 

(Applicable for HDL-MPTF02.48/46, 

HDL-MPTF04.48/46, HDL-MPTF06.48/46) 

 

 

 

 

 

 

 

 

Version: 1.0.0 

Published on Nov. 06, 2019

Содержание HDL-MPTF02.48/46

Страница 1: ...Prism Lite Series Touch Panel User Manual Applicable for HDL MPTF02 48 46 HDL MPTF04 48 46 HDL MPTF06 48 46 Version 1 0 0 Published on Nov 06 2019 ...

Страница 2: ...ontent Legal Statement I Update History II 1 Introduction 1 2 Basic Setting 3 3 Button Setting 5 3 1 Button Mode Setting 5 3 2 Button Status Setting 5 3 3 Target Setting 6 4 Button Status Color Setting 9 4 1 Button Status Color Setting 10 4 2 White Balance Adjustment 10 5 Sleep Group Setting 11 ...

Страница 3: ...ohibited without written authorization from HDL Any infringement of HDL s intellectual property rights will be investigated the legal liability The contents of this document will be updated as the updates of product versions or other reasons Unless otherwise agreed upon this document is to be used as a guidance only All the statements information and recommendations in this document makes no warra...

Страница 4: ...ation Co Ltd http www hdlautomation com II Update History The form below contains the information of every update The latest version contains all the updates of all former versions No Version Update Information Date 1 V1 0 0 Initial release Nov 06 2019 ...

Страница 5: ...ntroduce the configuration process of Prism Panel in Buspro Setup Tool 2 The devices include Prism Lite Series Touch Panel A computer with Buspro Setup Tool 2 1 Port Programming Gateway HDL MBUS01IP 431 connected to the router Dedicated Buspro cable s Notice Please refer to the datasheet attached to the product for the information of installation wiring specifications etc The pictures in this user...

Страница 6: ...ter Configuration Page 1 Connect the panel to the system and open Buspro Setup Tool 2 in the computer 2 Click Fast Search 3 Double click the Model or Description column to enter configuration page as shown in Figure 1 2 Figure 1 3 Figure 1 2 How to enter configuration page Figure 1 3 Configuration page ...

Страница 7: ...g information setting to enable disable timing analog broadcast or read panel voltage Broadcast temperature Built in temperature probe in Tile Panel enables temperature detection The temperature data can be broadcast to corresponding device if the Subnet ID and Device ID is set The temperature data can be adjusted with the slider Standby display and page setting Always ON enable keeping the panel ...

Страница 8: ...Prism Lite Series Touch Panel User Manual HDL Automation Co Ltd http www hdlautomation com 4 Figure 2 1 Basic information setting ...

Страница 9: ...r may set button mode and button button remarks on the left of Button Setting page 3 2 Button Status Setting Click Button Status button to open Button Status window as shown in Figure 3 2 This page includes the following setting options Status indicator to enable disable the status indicator of this button Dimming to enable disable the dimming function of this button Dimming value if enabled the p...

Страница 10: ...e ON Single OFF or Single ON OFF is selected Enter the button ID to link 2 buttons together for controlling one same target The target of the button with the smaller ID should prevail while 0 means no button is linked to this button Figure 3 2 Button status setting 3 3 Target Setting Select the button for target configuration on the left and click Target button on the right to open Target window a...

Страница 11: ...3 if 2 more targets is to be added as there s 1 target by default Thus enter from 1 to 3 in Input target number and click Read button 5 Then there will be 3 targets in the target list below 6 Click the target in target list and edit its Subnet ID Device ID Type and other parameters according to the selection of Type Click Save to save changes Notice About Target Creation Target Creation provides a...

Страница 12: ...es the targets of current template Figure 3 4 Target creation To edit template select the template in and edit in Template is only for saving the targets temporarily in order for editing and is not assigned to any button User may add the target to the button in the following 2 ways Drag the device in red part to corresponding button in red part Select the targets in multi selection with Shift Ctrl...

Страница 13: ...on Co Ltd http www hdlautomation com 9 4 Button Status Color Setting Click Others in configuration page as shown in Figure 4 1 Color Setting includes the following 2 setting options Button status color setting White balance adjust Figure 4 1 Color setting ...

Страница 14: ... color the indicator color when the target is on 2 Off color the indicator color when the target is off 3 Sensitivity to set the button sensitivity it is recommended to keep the value by default 4 2 White Balance Adjustment If the indicator color is not accurate please set the button indicator color to white in Button status color setting and edit the RGB value from 0 to 100 in White Balance Adjus...

Страница 15: ...by mode automatically similar to the mobile phone entering standby mode with no operation for a short period of time Sleep Group refers to the following situation if one panel is woke up from sleep standby mode other panels in the same sleep group will be woke up as well Through configuration one panel can send command for all the panels in the same sleep group to enter sleep mode Despite that the...

Страница 16: ...therwise the panel stays independent in the system and its sleep status does not affect other panels Add the panel to the corresponding sleep group by selecting Enable The system has 32 sleep groups by default Select Enable to add the panel to the corresponding sleep group and when the panel is woke up other panels in the sleep group will also be waken up ...