Operation 4
0020262548_00 Operating instructions
5
3.3
Zones
A building is divided into several zones if the heat demand
differs between different sections of the building.
–
If underfloor heating and radiator heating are installed in
a house.
–
If a house contains more than one independent residen-
tial unit.
If more than one zone is available, the system control con-
trols the available zones.
3.4
Hybrid manager
If a heat pump and an additional boiler are connected, you
can use the hybrid manager. If there is a heat demand, the
hybrid manager picks the heat generator that is more cost-
efficient. The hybrid manager decides which heat generator
to operate based on the tariffs that are set in relation to the
heat demand.
To ensure that the heat pump and the boiler can work effect-
ively and in synch with one another, the tariffs (
→
Page 14)
must be set correctly. If the tariffs are set incorrectly, this res-
ults in increased costs.
3.5
Frost protection function
The frost protection function protects the heating installa-
tion and flat from frost damage. The frost protection function
monitors the outdoor temperature.
If the outdoor temperature
–
falls below 4 °C, the system control switches the heat
generator on after a frost protection delay time, and
brings the target room temperature to 5 °C.
–
rises above 5 °C, the system control does not switch the
heat generator on but monitors the outdoor temperature.
Note
The competent person can set the frost protection
delay time.
3.6
Preventing malfunctions
▶
Ensure that room air can circulate freely around the sys-
tem control, and that the system control is not covered by
furniture, curtains or other objects.
▶
Ensure that all thermostatic radiator valves in the room
where the system control is fitted are fully open.
3.7
Avoiding moisture and mould damage
In heavily insulated rooms that only allow a small exchange
of air, moisture and mould damage may occur.
▶
Ventilate the rooms regularly by opening windows and
activate the
Ventilation boost
function once to save
energy.
Conditions
: Ventilation unit is connected
▶
Do not disconnect the ventilation unit from the power
mains.
▶
Clean and service the ventilation unit in accordance with
the instructions for the ventilation unit.
3.8
Identification plate
The identification plate is located inside the product and is
not accessible from the outside.
3.9
Serial number
You can call up the serial number to the display under
Menu
→
Information
→
Serial number
. The 10-digit article number
is located in the second line.
3.10
CE label
The CE label shows that the products comply with the basic
requirements of the applicable directives as stated on the
identification plate.
The declaration of conformity can be viewed at the manufac-
turer's site.
4
Operation
4.1
Operating structure
4.1.1
Adjustment and display levels
The product has two adjustment and display levels.
The end user level contains information and setting options
that you require as the end user.
End user level (
→
Page 19)
The installer level is reserved for the competent person. It is
protected by a code. Only competent persons may change
any settings in the installer level.
4.1.2
Menu structure design
The menu structure consists of several selection levels and a
setting level.
You can always use the selection button
Menu
to access
selection level 1 from the basic display.
You can use the selection button
Op. mode
to directly ac-
cess the setting level
Operating mode
.
The lowest level is always the setting level.
4.1.3
Selection level
Menu
Information
Desired temperatures
Time programmes
Back
Select
1
2
2
3
4
1
Scroll bar
2
Current function of the
selection button
3
List entries on the se-
lection level
4
Current selection level
The scroll bar
(1)
only appears if there are more list entries
than can be shown at once on the display.