Operation 4
0020262548_00 Operating instructions
7
4.3
Operating concept
The system control is operated using two selection buttons
and a rotary knob.
You can use the selection buttons to do the following:
–
Navigate through the selection levels and the setting
level in the menu structure.
–
Select a set value.
–
Confirm a set value.
–
Navigate to the operating modes.
–
Cancel changing a set value.
You can use the rotary knob to do the following:
–
Navigate through the list entries for a selection level.
–
Select a selection level or setting level.
–
Change a selected set value.
The display shows an element that is highlighted by white
writing on a black background. A flashing, highlighted value
means that you can change the value.
If you do not operate the system control for more than 10
seconds, the background lighting switches off.
If you do not operate the system control during a period of
more than 5 minutes, the basic display appears again.
4.3.1
Using the rotary knob to make settings in
the basic display
If the display shows the basic display, you can use the rotary
knob to change the setting for the desired temperature or
ventilation level.
The setting that you change depends on selecting the pre-
ferred display in the basic display, the selected operating
mode and the set mode for the operating mode.
4.3.1.1 Desired temperature in the Heating
operating mode
Change desired day temperature
18°C
For 6 hrs: wait 12 s
Permanent: Press OK
OK
Mode
Time
periods
Effect
Auto
On
Switch to another display view with the
request:
–
Permanent change to the
Day
temp. heating
–
Change to the
Day temp. heating
for six hours
Off
Direct change to the
Set-back temp.
heat.
for six hours
Mode
Time
periods
Effect
Day
Switch to another display view with the
request:
–
Permanent change to the
Day
temp. heating
–
Change to the
Day temp. heating
for six hours
Set-back
Direct change to the
Set-back temp.
heat.
for six hours
off
None
4.3.1.2 Desired temperature in the Cooling
operating mode
Mode
Time
periods
Effect
Auto
On
Direct permanent change to the
Day
temp. cooling
Off
None
Day
Direct permanent change to the
Day
temp. cooling
off
None
4.3.1.3 Ventilation level in the Ventilation operating
mode
Mode
Time
periods
Effect
Auto
On
Direct permanent change to the
Max.
vent. stage: Day
Off
Direct permanent change to the
Max.
vent. stge: Night
Day
Direct permanent change to the
Max.
vent. stage: Day
Set-back
Direct permanent change to the
Max.
vent. stge: Night
4.3.1.4 Desired temperature in the Manual cooling
advanced function
Mode
Time
periods
Effect
Activated
On
Direct permanent change to the
Day
temp. cooling
Off
None
4.3.1.5 Using the rotary knob to make settings with
no effect
You cannot influence the following advanced functions by
turning the rotary knob:
–
System OFF active
–
Cylinder boost
–
Party function
–
1 day at home
–
Days at home scheduling
–
1 day away from home
–
Days away from home scheduling
–
Ventilation boost
–
Screed-drying function