40
Installation and maintenance instructions ecoTEC plus 0020238195_07
Setting level
Values
Unit
Increment, select, explanation
Default
setting
Min.
Max.
Auxiliary relay
1
10
–
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extractor hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = eBUS remote control (not active)
9 = Legionella protection pump (not active)
10 = Solar valve (not active)
2
Accessory relay 1
1
10
–
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extractor hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = eBUS remote control (not active)
9 = Legionella protection pump (not active)
10 = Solar valve (not active)
2
Accessory relay 2
1
10
–
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extractor hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = eBUS remote control (not active)
9 = Legionella protection pump (not active)
10 = Solar valve (not active)
2
Contact data
Phone number
–
0-9
–
End the installation assistant?
–
–
–
Yes, No
–
¹
Fault lists are only displayed, and can only be deleted, if faults have occurred.
C
Overview of diagnostics codes
Setting level
Values
Unit
Increment, select, explanation
Default set-
ting
Own setting
Min.
Max.
d.00 Heating maximum output
–
–
kW
The maximum heating output varies
depending on the product.
→
Section "Technical data"
→
Section
"Technical
data"
Adjustable
d.01 Pump overrun time in
heating mode
1
60
min
1
5
Adjustable
d.02 Burner anti-cycling time
in heating mode
2
60
min
1
20
Adjustable
d.04 Water temperature in the
cylinder
Current value
℃
–
–
Not
adjustable
d.05 Determined target heating
flow temperature
Current value
℃
–
–
Not
adjustable
d.07 Target temperature for
the domestic hot water cylin-
der
Current value
℃
–
–
Not
adjustable
d.08 Status of the 230 V ther-
mostat
Current value
–
0 = Room thermostat open (no heat
requirement)
1 = Room thermostat closed (heat
requirement)
–
Not
adjustable
d.09 Target heating flow tem-
perature that is set on the
eBUS room thermostat
Current value
–
–
–
Not
adjustable