0020238195_07 ecoTEC plus Installation and maintenance instructions
9
4
Notes on the documentation
▶
Always observe all operating instructions enclosed with
the installation components.
▶
Store these instructions and all other applicable docu-
ments for further use.
These instructions apply only to:
Product article number
Article number
Gas Council
Number
VU 126/6-5 OVZ (H-GB)
ecoTEC plus 412
0010021220
41-694-13
VU 156/6-5 OVZ (H-GB)
ecoTEC plus 415
0010021221
41-694-14
VU 186/6-5 OVZ (H-GB)
ecoTEC plus 418
0010021222
41-694-15
VU 246/6-5 OVZ (H-GB)
ecoTEC plus 424
0010021223
41-694-16
VU 306/6-5 OVZ (H-GB)
ecoTEC plus 430
0010021224
41-694-17
VU 356/6-5 OVZ (H-GB)
ecoTEC plus 435
0010015674
41-044-76
5
Product description
5.1
CE marking
The CE marking shows that the products comply with the
basic requirements of the applicable directives as stated on
the declaration of conformity.
The declaration of conformity can be viewed at the manufac-
turer's site.
5.2
Hot Water Association
Vaillant is a full member of the Hot Water Association and
promotes the scheme in association with its cylinder range.
Details are available on the web site www.vaillant.co.uk
5.3
Serial number
The serial number is located on a plate behind the front flap.
The plate is in a plastic strap. You can also display the serial
number in the display.
5.4
Information on the data plate
The data plate is mounted on the underside of the product at
the factory.
The data plate keeps record of the country in which the
product is to be installed.
Information on the
identification plate
Meaning
Barcode with serial number
Serial number
For quality control purposes; 3rd and 4th
digits = year of production
For quality control purposes; 5th and 6th
digits = week of production
For identification purposes; 7th to 16th
digits = product article number
For quality control purposes; 17th to 20th
digits = place of manufacture
ecoTEC plus
Product designation
2H, G20
–
2 kPa
(20 mbar)
Factory setting for type of gas and gas
connection pressure
Cat.
Gas-fired boiler category
Condensing techno-
logy
Efficiency class of the boiler in accord-
ance with EC Directive 92/42/EEC
Type: Xx3(x)
Permissible flue gas connections
PMS
Maximum water pressure in heating
mode
PMW
Maximum water pressure in hot water
handling mode
V/Hz
Electrical connection
W
Max. electrical power consumption
IP
Level of protection
Heating mode
P
n
Nominal heat output range in heating
mode
P
nc
Nominal heat output range in heating
mode (condensing technology)
P
Nominal heat output range in hot water
handling mode
Q
n
Nominal heating load range in heating
mode
Q
nw
Nominal heating load range in hot water
handling mode
T
max.
Max. flow temperature
NOx
NOx class for the product
Code (DSN)
Specific product code
Read the instructions.
GC no.
Gas council number