36
Step 7
Required tools:
⚒
Assembly safety device
Assembly instructions:
1. Attach the assembly safety device to the transfer
guide using a screw clamp (to relieve the fixpoint
during connector installation).
5.3.5
Transfer guides
NOTICE!
►
One of the two transfer guides must be mounted
as a fixpoint.
►
The transfer guides may only have an air gap of
between 1 mm and 5 mm.
►
The lateral offset may not be more than 3 mm.
►
The vertical offset may not be more than 3 mm.
►
For assembly steps please refer to Chapter: