COMMISSIONING
32
5.3.3
Determining the system lengths
The conductor rail joints of the conductor system are manufactured with an air gap of 0.7mm +1mm. The pre-
cise system length can therefore only be roughly calculated. Generally, every system should be designed with
standard components. Standard components have the following lengths:
*Only if needed
Component
Length [mm]
Conductor system segment
4000
End segment, start
1000
End segment, end
1000
Component*
Length [mm]
Line feed
1000
Expansion joint
1000
Possible system lengths with 0.7 mm air gap at joint
Standard lengths
[mm]
Number of end seg-
ments
Number of straight
sections
Number of connectors
6001.40
2
1
2
10002.10
2
2
3
14002.80
2
3
4
18003.50
2
4
5
22004.20
2
5
6
26004.90
2
6
7
30005.60
2
7
8
34006.30
2
8
9
38007.00
2
9
10
42007.70
2
10
11
46008.40
2
11
12
50009.10
2
12
13
54009.80
2
13
14
58010.50
2
14
15
62011.20
2
15
16
66011.90
2
16
17
70012.60
2
17
18
74013.30
2
18
19
78014.00
2
19
20
82014.70
2
20
21
86015.40
2
21
22
90016.10
2
22
23
94016.80
2
23
24
98017.50
2
24
25
102018.20
2
25
26
106018.90
2
26
27