background image

 

SAFETY INSTRUCTIONS

11

2.7

Safety devices

WARNING!

Danger from non-functional safety devices!

Non-functional or disabled safety devices cause a risk of severe injuries or even death.

Before beginning any work, verify that all safety devices are functional and in-
stalled properly.

Never disable or override safety devices.

In addition to locally applicable safety regulations, the following safety instructions must be observed.

The following accident prevention regulations (UVV; Germany), respectively the new Accident Prevention Reg-
ulations – Principles of Prevention (DGUV Regulation 1; Germany) must always be observed.

2.8

Conduct in case of danger or accident

Precautions:

• Have first-aid equipment (first-aid kit, blankets etc.) and fire extinguisher ready.
• Maintain free access for emergency services vehicles.

Conduct in case of accident:

• Secure site of accident and call first aid personnel.
• Alert emergency services.
• Provide first aid

Содержание System 1

Страница 1: ...TRANSLATION OF THE ORIGINAL GERMAN OPERATING INSTRUCTIONS BATTERY CHARGING CONTACTS SYSTEM MANUAL INSTALLATION MANUAL MAINTENANCE MANUAL EN V 1 01...

Страница 2: ...vices 11 2 8 Conduct in case of danger or accident 11 2 9 Signage 12 3 Technical data 13 4 Layout and function 14 4 1 Brief system description 14 4 2 Assembly overview 15 4 2 1 System 1 15 4 2 2 Syste...

Страница 3: ...Troubleshooting table 31 7 Maintenance 32 7 1 Safety information about repairs 32 7 2 Maintenance 33 7 3 Maintenance intervals 34 7 4 Carbon brush 35 8 Transport and storage 36 8 1 Safety instructions...

Страница 4: ...n related to electricity that will result in death or serious injury unless avoided The actions to prevent the hazard are identified here WARNING The source of the hazard is described here This combin...

Страница 5: ...bination of a symbol and a signal word indicates a reference to another place in this text or in a different document The places in the text or references to other documents are identified here TIPS A...

Страница 6: ...eering as well as our years of knowledge and experience The manufacturer shall not be liable for damages resulting from Failure to observe the technical documentation Uses other than the intended use...

Страница 7: ...delivered product require the permission of the man ufacturer Genuine spare parts and manufacturer approved accessories provide safe ty The use of non approved parts voids any liability of the manufac...

Страница 8: ...transmission pilot function e g for CAN bus charging manage ment The following standards must be observed during operation with regard to personnel and property protection DIN EN 60204 1 DIN EN 60204...

Страница 9: ...ches control units pressure and sensing devices safety parts circuity breakers that have been used to unlock a system part or that can be used to connect electricity If this is not possible then the c...

Страница 10: ...rds that may arise from the special operating conditions at the instal lation site These must be implemented as facility instructions for the operation of the system Over the entire time the owner has...

Страница 11: ...sk Electrically qualified person see VDE 0105 100 Due to their professional training knowledge experience and knowledge of the relevant standards and regu lations professional electricians are able to...

Страница 12: ...ainst flying particles and liquid sprays Helmet Helmets protect against falling or flying parts and materials Gloves Gloves protect hands against chafing and abrasion cuts and punctures as well as aga...

Страница 13: ...egulations the following safety instructions must be observed The following accident prevention regulations UVV Germany respectively the new Accident Prevention Reg ulations Principles of Prevention D...

Страница 14: ...that the components are not live or in tension unauthorized approxima tion WARNING Hazard from illegible signs Over time labels and signs may become soiled or otherwise illegible so that hazards may...

Страница 15: ...ible with design modifications Technical specifications Voltage without ground conductor V DC V AC 60 25 1 Current load max at 100 duty cycle A 600 Operating temperature C 30 to 55 Operation in humid...

Страница 16: ...customer specific requirements the charging contacts and current collectors can be installed on the floor on the vehicle or as a charging station As a standard the charging contacts are operated on c...

Страница 17: ...rontal contact AGV floor contact Type BLK25 2 01 ID no 0590042 00 Number of poles 2 Charging current 100 duty cycle A 25 Weight kg 0 592 AGV current collector Type SA BLS50 2O 01 ID no 0590672 00 Numb...

Страница 18: ...0590736 00 Number of poles 2 Charging current 100 duty cycle A 100 Weight kg 0 588 AGV current collector Type SA BLS200 2 01 ID no 0590000 01 MS Number of poles 2 Charging current 100 duty cycle A 20...

Страница 19: ...0590001 00 Number of poles 2 Charging current 100 duty cycle A 200 Weight kg 2 542 Version Milled component AGV current collector Type SA BLS200 2QU 01 ID no 0590013 00 Number of poles 2 Charging cur...

Страница 20: ...es 2 Number of poles control current 2 Charging current 100 duty cycle A 100 Weight kg 0 614 for frontal contact with pilot function AGV floor contact Type BLK100 2 25 2 04 ID no 0590624 00 Number of...

Страница 21: ...poles control current 2 Charging current 100 duty cycle A 200 Weight kg 3 075 with cleaning brushes on front side for frontal con tact with pilot function AGV floor contact Type BLK200 2 25 2 01 ID no...

Страница 22: ...r frontal contact AGV current collector Type SA BLK200 1 02 ID no 0590036 00 Number of poles 1 Charging current 100 duty cycle A 200 Weight kg 0 944 AGV current collector Type SA BLS400 1O 02 ID no 05...

Страница 23: ...contact Type BLK600 1 01 ID no 0590044 00 Number of poles 1 Charging current 100 duty cycle A 600 Weight kg 3 241 AGV current collector Type SA BLS200 2E 01 ID no 0590065 00 Number of poles 2 Charging...

Страница 24: ...als tools and auxiliary devices been cleared from the danger zones Have the electrical system powered up by an authorized electrically trained person see chapter 2 3 1 Danger from electrical energy WA...

Страница 25: ...r when working on the conductor rail with tools Only tools that have not previously been used for ferritic materials may be used Use own tools for the different materials aluminum copper stainless ste...

Страница 26: ...crew head does not protrude from the contour and that the screw connection is secured against loosening e g Loctite threadlocker or locknut Changes to installation dimensions by prior agreement Increa...

Страница 27: ...n Nm 18 Disconnected height X mm approx 75 Lift tolerance mm 5 Permissible wear mm 2 Electrical connection X Assembly SA BLS100 InstallationdimensionsX mm 40 Torque connection Nm 5 Disconnected height...

Страница 28: ...s 1 Mount the current collector unit at the correct in stallation height Use the existing mounting bore holes or threaded inserts for this purpose NOTICE Make sure not to damage the carbon brush con n...

Страница 29: ...ys or buffer sections for example Mounting floor contact Prerequisites During mounting pay attention to any uneven ness of the surface The floor contact should evenly rest on as large an area as possi...

Страница 30: ...Required torque M6 8 Nm M8 15 Nm M10 18 Nm Option 1 BLK Connection CU connection tube The cable is connected to CU connection tubes which are connected to the CU contact plate Option 2 BLK connection...

Страница 31: ...s Check mechanical and electrical connections and re tighten if necessary Check the mobility of the carbon brushes and the free movement of the connection cable at the current collector Check the maxi...

Страница 32: ...on 6 2 Conduct in case of malfunction General principle If case of malfunctions that present an immediate hazard to persons or property immediately activate the safety devices Determine the cause of t...

Страница 33: ...rdance with the instructions A fault free sequence must be verified Malfunction Cause Remedy Periodic charging or loss of charging current Mechanical alignment Check the mechanicalalignment of the cha...

Страница 34: ...assembly site Before starting work follow the procedure described in paragraph Dangers due to electrical energy WARNING Danger due to insufficient qualification of persons Insufficiently qualified pe...

Страница 35: ...wing instructions must be observed DANGER Danger of life due to electrical current Contact with live parts can result in life threating injuries Make sure that the components are not live or in tensio...

Страница 36: ...brush springs in accor dance with 7 4 Carbon brush Check all electrical connections for corrosion Ensure that all fastening elements are properly tightened Check the maximum position offset depending...

Страница 37: ...rbon brush springs The contact pressure of the carbon brush springs must not fall below the values in the following table Measure the force required to push in the carbon brushes If the contact pressu...

Страница 38: ...t on the facilities NOTICE Transport instructions Never hold the unit by the carbon brushes or the power cable Always transport the unit holding it by the plastic base plate or by the collector plate...

Страница 39: ...e period Document and report the defects found 8 3 Storage Packaging When storing charging contacts or components care must be taken that the carbon brush contact surface and contact plate are protect...

Страница 40: ...WARNING Risk of death from improper replacement or removal Errors during the removal or replacement of components may cause life threatening situations or significant property damage Observe the safet...

Страница 41: ...that the products specified hereafter conform to the relevant EU regulations This declaration will be void when amendments not approved by us will be made to the products Battery changing system Paul...

Страница 42: ...F Floor contact connection 28 G Grounding and short circuiting 7 I Isolation 8 M Maintenance 34 O Operating company 8 Operation 29 Owner obligations 8 Q Qualifications 9 R Requirements to personnel 9...

Страница 43: ...CE Technical Documentation DQS certified in accordance DIN EN ISO 9001 2015 OHSAS 18001 2007...