COMMISSIONING
27
5.2.4
Mounting floor contacts
CAUTION!
►
Air and creepage distances according to IEC 60664-1 between phases and from phase to earth must be
taken into account for operation. Regional standards must be observed!
NOTICE!
Charging contacts can be mounted on the side, on the floor or overhead.
When mounting on the floor, observe the following:
►
The installation area must be outside the tracks of the vehicle wheels.
►
The installation area must be sufficiently marked in order to avoid driving over it with other vehicles and
tripping over the contact.
►
We recommend positioning in loading bays or buffer sections, for example.
Mounting floor contact
Prerequisites:
During mounting, pay attention to any uneven-
ness of the surface. The floor contact should
evenly rest on as large an area as possible.
Recesses should be as small as necessary. The
minimum bending radii of the connection lines in
particular must be taken into account in this re-
spect.
The plastic base plate should rest at least 15 mm
on the outer edges.
Assembly steps:
1. Place the floor contact in the intended position.
2. Fasten the floor contact according to the custom-
er drawing.
3. Connect the ground contact according to 5.2.5
Floor contact connection options and applicable
regulations.
4. Seal the edge area of the plastic base plate with
a suitable sealing material to protect the joint
area from liquid and dust ingress.