3
1. Yellow circuit –
The main circuit for lifting, lowering, bout marker arms
and
operation
of
front
tools.
2. Red circuit –
Circuit for hydraulic feed and hydraulic following harrow, if the
ma
chine is equipped with one.
See attachment 2 for tips on how to set the correct flow.
3. White circuit –
Operation of CrossBoard.
4. Green circuit –
If the machine is equipped with Autopilot (only ControlStation).
Circuit
Function
Require-
Approx. 30 l/
min
15–30 l/min
with variable
flow.
Approx. 10 l/
min
17/05/2016
RD 300-400S/C
1. Electrical installation on tractors
2. Installation of hydraulics
• Mount ControlStation or the iPad in the tractor cab. Position it within your field of vision
when looking forwards, and preferably so that you can reach it comfortably.
Tractor main
switch
Connect the GateWay cable if the tractor has an ISOBUS terminal.
Lock the terminal using the locking bolt (A).
If the tractor is not equipped with an ISOBUS terminal, connect the positive side of the power supply
cable – AFTER the main power switch.
The tractor’s main power
switch
Installation