RD 300-400S/C
1 Start
+
2 Fill sack
3 Pulses - - - - -
4 Sack 0.10 kg
5 Pulse/kg 1
6 Accept
7 Cancel
kg/ha
+ / -
10
%
Calibrate
0.0 kg/ha
+ / -
10
%
Calibrate
E X I T
0.0
1.
Press the B button to access the calibration menu.
2.
Enter the required seed application rate ( kg/ha) Press Enter.
3.
Use the selection dial to scroll down and enter the required
reduction/decrease of variable application rate in %. Enter.
4.
Page down to Calibrate and press Enter.
5.
Press the plus button for seed on the remote
or the plus button on the MiniRemote to fill
the feed rollers. The MiniRemote is on the left
side of the seed hopper.
6.
Empty the trays and place them back in
calibration position.
7.
Pour the seed from the tray into the calibra
tion bag and weigh the content.
8.
Enter the value on row 4 – Sack, and the
computer will calculate the number of pulses
per kilo (row 5).
It is also possible to manually enter the number of pulses per kg by pressing row 5 – Pulse/kg and turning the
selection dial to the value. Tip: Hold to increase feed rate.
Repeat the procedure for fertiliser and, where relevant, BioDrill.
7.
Press the ear button on the remote or
MiniRemote to fill the trays with grain.
Pulses are now counted for as long as the
button is pressed in.