background image

BaseSTATION 

 

Vaddio BaseSTATION - Document Number 342-0756 Rev A

    

      

           Page 17 of 40 

 

System Configuration and Programming 

Network Requirements and Information 

For the BaseSTATION and room PC, three (3) IP addresses are required; one (1) for BaseSTATION UC 
conferencing, one (1) for BaseSTATION VoIP conferencing and one (1) for the in-room PC used with the UC 
conferencing application.  The courtesy network jack on the BaseSTATION Dock can be used by the room PC, or 
any other network jack in the room that is on the same network as the BaseSTATION can be used.  

Broken record 

time:

  

It is very important to work with the IT professionals at the place of installation to get the IP addresses, the 

required VoIP information (see the worksheet) and the network jack required to install and operate each system.  

 

Accessing the BaseSTATION Web Pages 

The BaseSTATION has an embedded web server used for set-up and configuration.  
These internal webpages can be directly accessed by navigating to the URL with 
standard browsers.  The software defaults to DHCP and will attempt to dynamically 
obtain an IP address when connected to a network, but it will fall back to the default 
address of (169.254.1.1) if no DHCP server can be found.  Notes for both DHCP and 
Static configurations are provided below:

 

 

 

DHCP IP Set-up (Dynamic Host Configuration Protocol)  

Skip this section if Static IP is used.  If the LAN is using a DHCP (dynamic host configuration protocol) server, then 
the IP address, gateway and routing information will automatically be assigned.  The BaseSTATION will display the 
IP address when the answer/send button is held down for 3 seconds (see page 15).   

 

 

 

Static IP Set-up: 

The static IP can be assigned either through the network or directly to a computer using a cross-over cable.  
Depending on the age of the computer, you may not need a cross-over cable.  Either way the steps are the same 
for network or direct connection to a computer.  The default address of the BaseSTATION again is 169.254.1.1 and 
the Subnet mask is 255.255.0.0.  Different computer OS types all have their own way of doing things (without 
question), but they are essentially doing the same stuff, changing the IP address so the web pages of the device 
are accessible. 
 
 
 

 
BaseSTATION Web Page Tour 

Screen Shot:  Login 

Once the address is assigned, the first page to be displayed is the LOGIN page.  This login is really an 
administrator’s login.  The default username is:  

admin

.  The default password is: 

password

.  These names and 

passwords can be changed in the security section. 
 
 
 
 
 

 
 

 
 
 
 
 
 
 
 
 
 
 
 

Содержание BaseStation 999-8920-000

Страница 1: ...International 999 8925 000 BaseSTATION Premier System Premium Wall Mount and PC to Dock Interface Cable NA 999 8925 001 BaseSTATION Premier System Premium Wall Mount and PC to Dock Interface Cable Int...

Страница 2: ...BaseSTATION Vaddio BaseSTATION Document Number 342 0756 Rev A Page 2 of 40 Inside Front Cover Blank...

Страница 3: ...e 10 Setting the WideSHOT Lens on the BaseSTATION 11 Image Focus Knob Removal 11 Image Adjusting the HD Varifocal Optical Zoom Lens 11 First Time Set up with the BaseSTATION 12 Diagram Basic BaseSTATI...

Страница 4: ...Screen Shot Help Menu 25 Updating the BaseSTATION 26 Updating Instructions 26 BaseSTATION User Operations 28 Making a VoIP Call 29 Accepting a VoIP Call 29 Connecting to a PC s Audio 30 Image Screen...

Страница 5: ...ol and network A premium wall mounting system with integrated cable tray is included in the Deluxe and Premier packages Intended Use Before operating the device please read the entire manual thoroughl...

Страница 6: ...Cat 6 SSTP Shielded LINK Cable One 1 24 VDC 3 0 Amp Power Supply One 1 Euro Power Cable One 1 UK Power Cable One 1 Premium Wall Mount with cable tray and mounting hardware One 1 3 3 1m USB 2 0 Cable T...

Страница 7: ...TP cable is available as an accessory see below Due to the high speed communication between the BaseSTATION Dock and Camera Module please use only these two cabling options The Longer LINK Cable Optio...

Страница 8: ...utton On Off power button Press this button to turn the system on The green LED is illuminated when the system is on and in an operational state Push and hold the Power button for 3 01928 seconds and...

Страница 9: ...ystem uses a supplied 25 7 62m Cat 6 SSTP cable with individually shielded pairs to connect LINK ports A 50 15 24 m Cat 6 SSTP cable is available as an option The LINK port is marked in red on both si...

Страница 10: ...Camera Module front panel Image Connector Panel of the BaseSTATION Camera Module 1 Power Jack 5 5mm x 2 5mm coaxial power jack positive center Use only the provided 24 VDC 3 0 Amp switching power sup...

Страница 11: ...d focusing on the subject s at the distance that the camera will be used the iris can be adjusted to limit the amount of light that the image sensor receives which in turn gives an increased depth of...

Страница 12: ...alled users will be able to conduct Unified Communications UC sessions VoIP Teleconferencing or local presentations with the BaseSTATION Diagram Basic BaseSTATION System Connectivity One line Diagram...

Страница 13: ...n behind the monitor recommended deployment where all the cables are hidden from view allowing for a super clean installation Use the provided hardware to attach the wall mount to the wall The cable t...

Страница 14: ...Mount attached to wall with anchors and screws Camera Module with left side shown Place the Z Clips on the Z Cannel Camera Module Z Clips lowered down to lock on top of the Z Channel The top of the ca...

Страница 15: ...lity Reinvention of the wheel isn t required here Note Please do not plug the LINK cable into the Network RJ 45 incorrect termination is not typically a good thing especially when power is involved Im...

Страница 16: ...c functions of the camera The bottom line is simple give the camera a chance to work well in the room and excellent video is the result There are many room set up primers available on today s internet...

Страница 17: ...ress of 169 254 1 1 if no DHCP server can be found Notes for both DHCP and Static configurations are provided below DHCP IP Set up Dynamic Host Configuration Protocol Skip this section if Static IP is...

Страница 18: ...dio input for the BaseSTATION Dock When enabled the HDMI audio will be mixed into the Loudspeaker channels not recommended for conferencing applications Note Don t forget that the monitor has sound se...

Страница 19: ...ame quality of service QoS DSCP already set up within the user s voice data switches The ID and Priority must match the host network switches if the VLAN is enabled Please have IT guys provide this in...

Страница 20: ...referred codec to be used during the call negotiation The codec types will change position with the up or down arrows that are next to each setting Audio Processing Various audio processing functions...

Страница 21: ...ost applications the Auto functions will be sufficient and should only be used to combat poor lighting or improper background shots such as all black or all white backgrounds The Detail control adjust...

Страница 22: ...IP address can also be obtained from the BaseSTATION by pressing and holding the green Answer button on the BaseSTATION Dock for 3 0 seconds The current IP and MAC address will be displayed for 10 se...

Страница 23: ...a local PC Screen Shot System Menu The System menu is intended to display the software versions and to provide for future firmware update operations The administrator can select the new firmware file...

Страница 24: ...tion pop up menu appears to allow the admin a chance to cancel and provide instructions on how to proceed Always read and follow the instructions and warnings for all pop up confirmation menus Screen...

Страница 25: ...rovides general information about the BaseSTATION and assists the administrator in configuring and programming of the device The Help menu also includes information on the current firmware release loa...

Страница 26: ...the VaddioSTATION administrator web pages Default username is admin and default password is password unless changed by the administrator 3 Navigate to the Systems tab within the web pages Press the Ch...

Страница 27: ...ument Number 342 0756 Rev A Page 27 of 40 6 After the update has been completed a reboot will not be needed Go to the System menu and the new versions of Audio Video In Video Out VoIP and the overall...

Страница 28: ...f multiple video sources are connected to the Dock and allow either the camera input HDMI or the VGA PC inputs to be routed to the room s monitor and to the far end PIP On Off This button toggles the...

Страница 29: ...essing the Hang up button will clear the number allowing re entry Step 2 Once the desired number is entered Press the Send button The OSD will indicate that a call is trying to be established to the o...

Страница 30: ...soft client Lync WebEx Skype etc Go to the control panel sound playback and select VaddioSTATION as the default Playback device Image Screen Shot VaddioSTATION Selected for Playback The HDMI audio wil...

Страница 31: ...s PC Camera The BaseSTATION emulates a USB Web Camera to the PC VaddioSTATION below must be selected as the source with any software application Once connected to the PC via USB it will be depicted as...

Страница 32: ...th known issues and errata Windows 7 Windows 8 Linux Evolving Compatibilities As more UC soft client and lecture capture programs are released and gain popularity Vaddio will provide a continuing rese...

Страница 33: ...number e mail address shipping address product serial numbers and original purchase order number Describe the reason for repairs or returns as well as the date of purchase See the General RMA Terms a...

Страница 34: ...operate this equipment ICES 003 Compliance This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of...

Страница 35: ...ded pairs with overall shield gold contacts and metal shielded RJ 45 Printed on Jacket Cat 6 26 AWG x 4pr SSTP IEC 60332 1 Conforms to ISO IEC 11801 EN 50288 ANSI TIA EIA 568 C 2 3P ETL Verified CMX U...

Страница 36: ...fill 3 If Static then the following information is needed the MAC address is provided IP Address _________________________________________________ Subnet Mask _________________________________________...

Страница 37: ...be in order to be detected Comfort Noise Enabled Check to Enable Synthetic background noise used to fill the artificial silence of digital Comfort Noise Threshold Default 63dBu Silence Suppression Ch...

Страница 38: ...BaseSTATION Vaddio BaseSTATION Document Number 342 0756 Rev A Page 38 of 40 System Configuration Notes...

Страница 39: ...BaseSTATION Vaddio BaseSTATION Document Number 342 0756 Rev A Page 39 of 40 Inside Back Cover Blank...

Страница 40: ...All Rights Reserved Reproduction in whole or in part without written permission is prohibited Specifications and pricing are subject to change without notice or obligation Vaddio BaseSTATION HuddleSTA...

Отзывы: