page 39 of 92
• Reduce the transmission of vibration. Pre
-
vent mechanical load due to rigid pipelines.
Insert elastic hoses or flexible elements
as couplings between the pump and rigid
pipes.
Note
: Flexible elements will compress or
flatten when evacuated if not designed for
use under vacuum.
• Hose connections at the pump inlet must al
-
ways be gas tight.
MD 1C + AK + EK:
Assembling the hose nozzle with union nut:
➨
Take the hose nozzle with attached com-
pression ferrule and union nut out of the
catchpot and put onto inlet connection.
➨
Tighten the union nut by hand until you can
feel the stop. Then tighten an additional 1/4
rotation with an open-ended wrench (size
17mm) for final installation.
Use connecting hoses with large diameter and
keep them as short as possible to avoid flow
losses. Locate the pump as closely as possi
-
ble to the application.
NOTICE
✘
✔
Secure hose connections at the pump ap-
propriately, e.g., with hose clamps, to protect
against accidental detachment.
NOTICE
+
Particles and dust must not be aspirated. If necessary,
you must install appropriate filters. You must ensure
their suitability concerning gas flow, chemical resis
-
tance and resistance to clogging prior to use.
Содержание MZ 1C
Страница 30: ...page 30 of 92 MD 1C MD 1C C US only pump with dual voltage motor 7 10 11 6 9 8 5 4 3 2 3 2 3 2 ...
Страница 31: ...page 31 of 92 MZ 1C 3 2 7 10 11 6 9 8 ...
Страница 32: ...page 32 of 92 MD 1C AK EK 10 3 6 1 8 2 9 7 15 16 17 13 11 8 14 19 18 ...
Страница 33: ...page 33 of 92 MD 1C VARIO SP 7 10 6 12 11 8 Ensure sufficient venting of the pump ...
Страница 63: ...page 63 of 92 Checking diaphragms and valves 1 2 3 MD 1C AK EK 10 mm 2 5 mm MD 1C AK EK MD 1C AK EK 5 1x ...
Страница 64: ...page 64 of 92 4 3A 5 MD 1C size 2 2x 1 17 mm 14 mm max 1 4 ...
Страница 66: ...page 66 of 92 6 7 8 4 6x Clean ...
Страница 67: ...page 67 of 92 9 Replacing the diaphragm 10 11 20696828 20696838 ...
Страница 68: ...page 68 of 92 12 1 2 3 13 14 Pay attention to number of washers ...
Страница 69: ...page 69 of 92 15 16 17 Pay attention to number of washers ...
Страница 70: ...page 70 of 92 18 1 2 19 20 4x Replacing the valves and assembling the pump heads ...
Страница 71: ...page 71 of 92 21 22 23 ...
Страница 73: ...page 73 of 92 27 28 1 2 28A size 2 2x 17 mm 10 mm MD 1C AK EK 5 1x MD 1C ...
Страница 74: ...page 74 of 92 29 30 31 Assembling the connecting hose MD 1C AK EK 2x ...
Страница 77: ...page 77 of 92 5 6 4 20638821 20638821 ...
Страница 89: ...page 89 of 92 ...
Страница 90: ...page 90 of 92 ...
Страница 91: ...page 91 of 92 ...