![VACUTEC Smart Pressure Diagnostic Smoke WV711 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/vacutec/smart-pressure-diagnostic-smoke-wv711/smart-pressure-diagnostic-smoke-wv711_instruction-manual_3123863008.webp)
4
Product Overview,
continued
Control Panel Overview
A
B
C
D
E
F G
A.
Test Mode Lights:
indicate if Tester is set to measure pressure in PSI, pressure in bar, or flow in liters
per minute, all of which are controlled by MODE Button (B) and displayed in the Digital Display (F).
B.
Mode Button:
selects test modes, turning on appropriate Test Mode Light (A).
C.
UP Arrow Button:
selects desired test pressure and/or increases test pressure.
D.
DOWN Arrow Button:
selects desired test pressure and/or decreases test pressure.
E.
ON/OFF Button:
‘ON’ starts a 10 minute test cycle and illuminates the green light (G). Test cycle
automatically turns ‘OFF’ after 10 minutes (or if manually turned off) and goes into OFF/DECAY setting,
turning on yellow OFF/DECAY light (G).
F.
Digital Display:
shows selected setting: pressure in PSI, pressure in bar, or flow in L/M. Also verifies if
system being tested has decay (leak), indicated by if either pressure setting on display stays stable or
decreases.
G.
Function Lights:
green ‘ON’ light turns on when ‘ON’ button (E) is pressed. Yellow OFF/DECAY light
turns on when ‘OFF’ button (E) is pressed, turning Tester off and starting a decay test. Red POLARITY
light turns on if battery power cables are reversed on the battery power supply.