VACUTEC Smart Pressure Diagnostic Smoke WV711 Скачать руководство пользователя страница 4

 

 

iv  

 

Contents 

 

Caution & Usage Tips 

Specifications 

Included Accessories 

Optional Accessories 

Product Overview  

Initial Setup 

Quick Start Guide 

Basic Test Procedure 

Leak Samples 

LED Display Codes 

Programming Remote Control Fob 

Programming PSI or BAR Pressure Setting 

Warranty 

 

iii 

iii 

3-4 

10 
10 

11 

Thank You and Congratulations!

  Your Smart Pressure® leak detector, which incorporates STAR Diagnostic 

Smoke® Technology 

inside

, is the simplest and quickest way to find many vehicle system leaks.  Smoke 

vapor-generating leak detectors containing STAR Technology are the only leak detectors in the world 
internationally-mandated by automakers (OEMs).

 

  

 

Unlike conventional high pressure smoke machines, Smart Pressure® technology produces the densest 
visible smoke vapor over the Tester’s 

entire 

operating pressure range.  Smart Pressure® technology 

software prevents thinning of smoke density that occurs when conventional analog units are set at high 
pressure.  A denser smoke vapor means it's easier to see at leak points.  And setting the test pressure is 
fully automatic and could not be simpler. 

 

At high pressure, the smoke vapor escaping a leak can be very difficult to see with a conventional smoke 
machine.  However, this Smart Pressure® leak detector contains UltraTrace

UV

® smoke-producing solution, 

which is an essential feature for high pressure leak testing.  The vaporized UltraTrace

UV

® solution 

deposits a trace dye at the exact location of the leak(s).  

You simply cannot find all high pressure leaks 

without it! 

    

 

The patented technology 

inside

 your Tester, including the UltraTrace

UV

®, was designed in collaboration 

with major OEMs, in order to establish a contaminant-free standard for leak detection.  It is designed to 
be safe for vehicle systems and will not void factory warranties.   

 

Содержание Smart Pressure Diagnostic Smoke WV711

Страница 1: ...re Diagnostic Smoke Machine with UltraTraceUV Non Contaminant Dye Solution Model No WV711 Leak Detection Systems for the Professional Technician USA Canada Euro Patents 6 392 227 6 439 031 6 526 808 2 279 147 2 394 911 1 384 984 Other Patents Pending ...

Страница 2: ...ii ...

Страница 3: ...tions Connect Tester s black cable to chassis ground when using Battery Cables WVA 40 Use UltraTraceUV Smoke Solution No WV0712UV in Tester Using a non approved solution can cause damage to vehicles being tested and may cause personal injury Do not leave Tester s hose or power cables connected to the vehicle if tests are not being performed Do not perform test near source of spark or ignition Wear...

Страница 4: ...ire operating pressure range Smart Pressure technology software prevents thinning of smoke density that occurs when conventional analog units are set at high pressure A denser smoke vapor means it s easier to see at leak points And setting the test pressure is fully automatic and could not be simpler At high pressure the smoke vapor escaping a leak can be very difficult to see with a conventional ...

Страница 5: ... the fluorescent dye deposited at the exact location of a leak Also has laser pointer to view laser reflections on exiting vapor Remote Control WVA 073 Plug in Battery Cables WVRP 40 connects to WV711 and 12VDC battery Supply Hose Male Fitting sourced locally it is the same fitting as is attached to optional adapter kit WVA 091 It is the matching coupler to the female connection at the end of the ...

Страница 6: ...o smoke tester and grounded wall power outlet to avoid using the vehicle battery as a power source AC input 100 240V AC 5A 50 60Hz DC output 12V 25A Nitrogen Tank Pressure Regulator WVA 051 preset 100 PSIG 6 9 bar regulator connects directly onto nitrogen cylinder and coiled hose WVA 041 in the event test specifications requires nitrogen instead of compressed air x 25 Coiled Nitrogen Hose WVA 041 ...

Страница 7: ...nally see drainage of fluid from this port But excessive drainage indicates your air compressor requires draining and or a filter system IMPORTANT NOTE In order for the moisture and contaminants that collect in the filter bowl of the Tester to drain the air supply to the Tester must be disconnected and re connected at the Tester s Air Fitting So do not leave air supply to the Tester connected for ...

Страница 8: ...FF Button ON starts a 10 minute test cycle and illuminates the green light G Test cycle automatically turns OFF after 10 minutes or if manually turned off and goes into OFF DECAY setting turning on yellow OFF DECAY light G F Digital Display shows selected setting pressure in PSI pressure in bar or flow in L M Also verifies if system being tested has decay leak indicated by if either pressure setti...

Страница 9: ...tion Read instruction in its entirety prior to using this Tester Pour entire contents of two 12 oz UltraTraceUV solution bottles into the smoke chamber NOTE Check solution level regularly and maintain at or near FULL mark If not supplied install correct air gas fitting onto the Tester Low Full ...

Страница 10: ... 3 4 to 12 bar The internal pressure regulator in the WV711 Tester sets the test pressure 3 43 5 PSIG 0 21 to 3 bar according to your settings 2 a Connect power cord onto back of Tester c To remove pull white tab b Push white tab forward to locked position d Push inner section downward while at the same time pulling plug away from Tester a b c d Or Regulator WVA 051 Pressure line from Regulator to...

Страница 11: ...w test pressures NOTE If possible it is best to purge the non smoke air out of the system by leaving an opening in the system being filled Close the system once smoke exits that opening and continue to fill with smoke This quickly fills the system with Diagnostic Smoke 7 Once system is full use UV light provided to look for UV deposit s at leak point s The laser light provided will see a leak by r...

Страница 12: ...8 Leak Sample Three Ways to See the Leak UV light sees the dye trace White light highlights the smoke Laser light is reflected by the smoke vapor ...

Страница 13: ... Battery or Bad Battery Connection shown in two consecutive displays E01 Open Circuit ground or power E02 There is pressure in the system to be tested cannot calibrate NOTE this error code will be followed by the amount of pressure in the system to be tested Relieve pressure in the system to be tested prior to continuing with the test n0A No Air no air gas connected to tester PSI Set to read PSI p...

Страница 14: ... now read End indicating the remote is now programmed to the Tester 6 Disconnect and reconnect Tester from power to resume normal operations Setting Pressure Reading Default to PSI or BAR Your Tester has been preset at the factory to either default to PSI or BAR readings Follow the steps below to change the default setting 1 Disconnect Tester from power 2 Connect Tester to workshop air 3 While pre...

Страница 15: ...or Inc Warrants To the Original Purchaser under normal use care and service Tester shall be free from defects in material and workmanship for ONE YEAR from the date of original invoice Seller s obligations under this warranty are limited solely to the repair or at Seller s option replacement of or refund of the original purchase price for Equipment or parts which to Seller s satisfaction are deter...

Страница 16: ......

Отзывы: