INSTRUCTION MANUAL 

 

 

 

 

 

 

 

 

 

 

 

 

Smart Pressure®

 

Variable Pressure Diagnostic Smoke

®

 

Machine

 

with UltraTrace

UV

®

 

Non-Contaminant Dye Solution 

Model No. WV711 

 

 

Leak Detection Systems for the Professional Technician 

 

 

 

USA | Canada | Euro | Patents: 6,392,227 • 6,439,031 • 6,526,808 | 2,279,147 • 2,394,911 | 1,384,984 | Other Patents Pending

 

 

  

Содержание Smart Pressure Diagnostic Smoke WV711

Страница 1: ...re Diagnostic Smoke Machine with UltraTraceUV Non Contaminant Dye Solution Model No WV711 Leak Detection Systems for the Professional Technician USA Canada Euro Patents 6 392 227 6 439 031 6 526 808 2 279 147 2 394 911 1 384 984 Other Patents Pending ...

Страница 2: ...ii ...

Страница 3: ...tions Connect Tester s black cable to chassis ground when using Battery Cables WVA 40 Use UltraTraceUV Smoke Solution No WV0712UV in Tester Using a non approved solution can cause damage to vehicles being tested and may cause personal injury Do not leave Tester s hose or power cables connected to the vehicle if tests are not being performed Do not perform test near source of spark or ignition Wear...

Страница 4: ...ire operating pressure range Smart Pressure technology software prevents thinning of smoke density that occurs when conventional analog units are set at high pressure A denser smoke vapor means it s easier to see at leak points And setting the test pressure is fully automatic and could not be simpler At high pressure the smoke vapor escaping a leak can be very difficult to see with a conventional ...

Страница 5: ... the fluorescent dye deposited at the exact location of a leak Also has laser pointer to view laser reflections on exiting vapor Remote Control WVA 073 Plug in Battery Cables WVRP 40 connects to WV711 and 12VDC battery Supply Hose Male Fitting sourced locally it is the same fitting as is attached to optional adapter kit WVA 091 It is the matching coupler to the female connection at the end of the ...

Страница 6: ...o smoke tester and grounded wall power outlet to avoid using the vehicle battery as a power source AC input 100 240V AC 5A 50 60Hz DC output 12V 25A Nitrogen Tank Pressure Regulator WVA 051 preset 100 PSIG 6 9 bar regulator connects directly onto nitrogen cylinder and coiled hose WVA 041 in the event test specifications requires nitrogen instead of compressed air x 25 Coiled Nitrogen Hose WVA 041 ...

Страница 7: ...nally see drainage of fluid from this port But excessive drainage indicates your air compressor requires draining and or a filter system IMPORTANT NOTE In order for the moisture and contaminants that collect in the filter bowl of the Tester to drain the air supply to the Tester must be disconnected and re connected at the Tester s Air Fitting So do not leave air supply to the Tester connected for ...

Страница 8: ...FF Button ON starts a 10 minute test cycle and illuminates the green light G Test cycle automatically turns OFF after 10 minutes or if manually turned off and goes into OFF DECAY setting turning on yellow OFF DECAY light G F Digital Display shows selected setting pressure in PSI pressure in bar or flow in L M Also verifies if system being tested has decay leak indicated by if either pressure setti...

Страница 9: ...tion Read instruction in its entirety prior to using this Tester Pour entire contents of two 12 oz UltraTraceUV solution bottles into the smoke chamber NOTE Check solution level regularly and maintain at or near FULL mark If not supplied install correct air gas fitting onto the Tester Low Full ...

Страница 10: ... 3 4 to 12 bar The internal pressure regulator in the WV711 Tester sets the test pressure 3 43 5 PSIG 0 21 to 3 bar according to your settings 2 a Connect power cord onto back of Tester c To remove pull white tab b Push white tab forward to locked position d Push inner section downward while at the same time pulling plug away from Tester a b c d Or Regulator WVA 051 Pressure line from Regulator to...

Страница 11: ...w test pressures NOTE If possible it is best to purge the non smoke air out of the system by leaving an opening in the system being filled Close the system once smoke exits that opening and continue to fill with smoke This quickly fills the system with Diagnostic Smoke 7 Once system is full use UV light provided to look for UV deposit s at leak point s The laser light provided will see a leak by r...

Страница 12: ...8 Leak Sample Three Ways to See the Leak UV light sees the dye trace White light highlights the smoke Laser light is reflected by the smoke vapor ...

Страница 13: ... Battery or Bad Battery Connection shown in two consecutive displays E01 Open Circuit ground or power E02 There is pressure in the system to be tested cannot calibrate NOTE this error code will be followed by the amount of pressure in the system to be tested Relieve pressure in the system to be tested prior to continuing with the test n0A No Air no air gas connected to tester PSI Set to read PSI p...

Страница 14: ... now read End indicating the remote is now programmed to the Tester 6 Disconnect and reconnect Tester from power to resume normal operations Setting Pressure Reading Default to PSI or BAR Your Tester has been preset at the factory to either default to PSI or BAR readings Follow the steps below to change the default setting 1 Disconnect Tester from power 2 Connect Tester to workshop air 3 While pre...

Страница 15: ...or Inc Warrants To the Original Purchaser under normal use care and service Tester shall be free from defects in material and workmanship for ONE YEAR from the date of original invoice Seller s obligations under this warranty are limited solely to the repair or at Seller s option replacement of or refund of the original purchase price for Equipment or parts which to Seller s satisfaction are deter...