Initial Setup
1
.
Low Full
a. Pour entire contents of one 12 oz. UltraTraceUV® solution bottle into the smoke chamber.
NOTE: Use second bottle supplied to regularly maintain at or near FULL mark.
2
.
b. If not supplied; install correct air fitting onto the
Leak
finder
®. Use Teflon® thread-
sealer. Be sure the thread-sealer is not allowed to enter the nitrogen generator’s housing.
Connect workshop air to air fitting. Set air pressure between 3.4 to 10.3 bar (50 ~ 150 PSIG).
3.
c. Connect power cord and push white
tab toward tester to lock position.
To remove plug:
1. Pull white tab to unlock.
2. Push inner tab downward, while at the
same time pulling plug away from tester.
Bleed Hole
Air fitting
NOTE:
The nitrogen generator naturally expels oxygen during the nitrogen-generation process. It is normal
to hear a small amount of oxygen exiting the generator’s
bleed hole
when connected to workshop air.