![VACUTEC Leakfinder WV622N-VWKIT Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/vacutec/leakfinder-wv622n-vwkit/leakfinder-wv622n-vwkit_instruction-and-operation-manual_847888010.webp)
7
Control Valve Overview
TEST
:
Delivers nitrogen, without smoke, and a
very accurate flow meter reading. This setting
is for determining if a leak exists and how large
it is.
NOTE:
Leak size is discussed in
Basic EVAP Test
section of manual.
SMOKE
:
Delivers maximum smoke volume.
FLOW CONTROL:
Controls smoke volume.
>
Locating the leak source is sometimes easier
with less smoke volume. First, fill system with
smoke, at full volume, then reduce volume
while still introducing smoke.
Note: Flow Control does not affect delivery
pressure; it only affects flow volume.