![VACUTEC Leakfinder WV622N-VWKIT Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/vacutec/leakfinder-wv622n-vwkit/leakfinder-wv622n-vwkit_instruction-and-operation-manual_847888011.webp)
8
Basic Test Procedure
1.
a. Connect red clip to 12V-DC power.
b. Connect black clip to chassis ground.
c. Use adapter cone supplied to access intake/
induction system and connect smoke supply hose
to adapter cone.
Be sure and completely unwind smoke supply hose when connecting to the
vehicle. A hose that is left wound up will collect excessive smoke vapor
inside the hose which may impede smoke vapor flow through the hose. If
this occurs, allow the supply hose to drain prior to its next use.
2.
a. Position to SMOKE (full flow).
b. Press START button.
> Green and red lights turn <ON>.
>
A blinking green light indicates a weak battery.
>
System is on a 5-minute timer.