Control keypad
vacon • 67
24-hour support: +358-40-8371 150 • Email: [email protected]
7
T6.8.2.4
Operating hours trip
counter
hh:mm: ss
P6.8.2.5
Clear operating time
counter
0 = No action
1 = Clear
T6.8.2.3, T6.8.2.4
S6.8.3
I6.8.3.1 Software
package
Scroll information with menu
button right
I6.8.3.2
System SW version
I6.8.3.3 Firmware
interface
I6.8.3.4 System
load
%
S6.8.4
S6.8.4.1 Application
A6.8.4.1.1 Application
id
A6.8.4.1.2 Application
version
A6.8.4.1.3 Firmware
interface
S6.8.5
I6.8.5.2 Unit
voltage
V
I6.8.5.3 Brake
chopper
0=Not present, 1=Present
S6.8.6
S6.8.6.1
Slot E OPT-
Note! the submenus are not
showing if no option board is
installed
I6.8.6.1.1
Slot E Status
1
5
1=Connection lost
2=Initializing
3=Run
5=Fault
I6.8.6.1.2 Slot E Program version
S6.8.6.2
Slot D OPT-
Note! the submenus are not
showing if no option board is
installed
I6.8.6.2.1
Slot D Status
1
5
1=Connection lost
2=Initializing
3=Run
5=Fault
I6.8.6.2.2
Slot D Program
version
S6.9
AI mode
P6.9.1
1
0
0=Voltage input
1=Current input
(Types MF4 – MF6)
P6.9.2
1
1
0=Voltage input
1=Current input
S6.10
Fieldbus parameters
I6.10.1
P6.10.2
1 1
1
0=Not used
1=Modbus protocol
P6.10.3
1
255
1
Addresses 1 – 255
P6.10.4
8
5
0=300 baud
1=600 baud
2=1200 baud
3=2400 baud
4=4800 baud
5=9600 baud
6=19200 baud
7=38400 baud
8=57600 baud
P6.10.5
0 1 0
0=1 1=2
P6.10.6
0=None 1=Odd 2=Even
P6.10.7
0 300 s
0
0=Not used1=1 second
2=2 seconds, etc
Table 7-5. System menu functions