background image

THE CABLE AND FUSE SIZES FOR VACON

®

 20 X IN NORTH AMERICA, 

MAINS VOLTAGE 208-240 V AND 380-500 V

THE TIGHTENING TORQUES OF CABLE TERMINALS

Frame

Type

IL

[A]

Fuse

(class T)

[A]

Mains and

motor cable

Cu

Terminal cable size

Main terminal

Earth terminal

MU2

0004 2 

0003 4 - 0004 4

4.3 

3.2 - 4.0

6

AWG14

AWG24-AWG12

AWG17-AWG10

0005 2 - 0007 2 

0005 4 - 0006 4

6.8 - 8.4 

5.6 - 7.3

10

AWG14

AWG24-AWG12

AWG17-AWG10

0008 4

9.6

15

AWG14

AWG24-AWG12

AWG17-AWG10

MU2 

1-phase

0004 2

8.3

20

AWG14

AWG24-AWG12

AWG17-AWG10

0005 2

11.2

20

AWG14

AWG24-AWG12

AWG17-AWG10

0007 2

14.1

25

AWG14

AWG24-AWG12

AWG17-AWG10

MU3

0011 2 

0009 4

13.4 

11.5

15

AWG14

AWG20-AWG6

AWG17-AWG10

0012 2 

0012 4

14.2 

14.9

20

AWG12

AWG20-AWG6

AWG17-AWG10

0017 2 

0016 4

20.6 

20.0

25

AWG10

AWG20-AWG6

AWG17-AWG10

Frame

Type

Tightening torque 

Power and motor 

terminals

Tightening torque 

EMC grounding clamps

Tightening torque 

Grounding 

terminals

[Nm]

lb-in.

[Nm]

lb-in.

[Nm]

lb-in.

MU2

0003 4—0008 4 

0004 2—0007 2

0.5—0.6

4.5—5.3

1.5

13.3

2.0

17.7

MU3

0009 4—0016 4 

0011 2—0017 2

1.2—1.5

10.6—13.3

1.5

13.3

2.0

17.7

TIGHTENING TORQUE OF NPT ADAPTERS TO METRIC THREADS CABLE ENTRIES

Frame

Thread male 

metric

Thread male 

NPT

Tightening torque

[Nm]

lb-in.

MU2

M20

1/2”

2.0

17.7

M25

3/4”

4.0

35.5

MU3

M25

3/4”

4.0

35.5

M20x1.5

M25x1.5

M16x1.5

M25x1.5

M16x1.5

M25x1.5

CABLE ENTRIES, MU2 AND MU3 INSTALLATIONS

MU2

MU3

NPT adapter order information

M20: ADEC M20-T12
M25: ADEM M25-T34

Отзывы: