8 9
1. Remove power head and place in upside down position.
2. Slide the cartridge filter down over the filter cage and carefully push filter in until it
stops against the power head. (fig.1 & 2)
3. Place filter retainer on top of cartridge filter and tighten down by turning retainer
handle clockwise. (fig.3 & 4)
Removing and Cleaning Cartridge Filter
1. Unlock and remove the filter retainer by tuning retainer handle counter clockwise.
2. Carefully hold and pull the cartridge filter up for removal. (fig.5)
3. Clean the cartridge filter by gently tapping or brushing dirt off. Cleaning should
not be done indoors in living areas. For optimal performance a new filter is
recommended.
4. Install cleaned or new filter into place as instructed above in steps 2 and 3 of
installing Cartridge Filter.
5. Wet filters should be removed and allowed to air dry for 24 hours before installing
onto the filter cage.
1
3
2
4
I
NSTALLING & CLEANING FOAM SLEEVE FILTER
Installing Foam Sleeve Filter
1. Remove power head and place in upside down position. Follow instructions to
remove cartridge filter.
2. Carefully slide foam sleeve filter down over the filter cage making sure the whole
cage is covered.(fig.1 & 2)
3. Replace the power head on to the container.
Cleaning Foam Sleeve Filter
1. With the removed power head in the upside down position, carefully remove foam
sleeve filter. (fig. 3)
2. Use a mild soap and water solution to wash foam sleeve filter and rinse with clean
water. (fig. 4)
3. Allow filter to air dry before installing and using again.
1
3
2
4
T
ROUBLESHOOTING
Symptom
Possible Causes
Corrective Action
Vacuum will not
operate
1) No power supply.
1) Check power supply – cord,
breakers, fuses.
2) Faulty power cord.
2) Unplug and check the
power cord. If damaged,
have it repaired by a
professional.
3) Container full.
3) Empty container.
Dust comes out
from motor cover.
1) The PET cartridge
filter or collection bag
is missing or damaged.
1) Attach or replace PET
cartridge filter or collection
bag.
Reduced
efficiency and
motor/speed
vibration.
1) There is a blockage in
the nozzle or hose,
or the container inlet.
Or dust filter blocked
by fine dust.
1) Check nozzle, hose and
container inlets for
blockage. Take off the filter
and clean it. Or install new
cartridge filter.
Содержание VK1650SWD 950091