| 6
100–220V
0.25A
min 3.5 in
(8.9 cm)
32
–
42
in
(81.
3–10
6.7
cm
)
min 24 in (61 cm)
min 9.6 in
(24.4 cm)
• Power to the desired location must be 100 to 220V single-phase AC, 0.25 amp, or Power
over Ethernet that meets standards 802.3af or 802.3at.
• Minimum dimensional requirements must be met.
• You must supply conduit and wire for the electrical connection.
• Ideal installation locations include columns, walls near doors and walls outside restrooms.
Fixture should be installed in drywall.
• The National Fire Protection Association requires that sanitizing dispensers be at least 1
in (2.5 cm) from any ignition source, including outlets, and cannot be located in the area
directly above an ignition source.
CHOOSING YOUR INSTALLATION LOCATION