ENGLISH
- 43 -
PARAMETER
VALUE
DESCRIPTION
DEFAULT
MEMO
LUCi
Courtesy lights
This menu allows setting the automatic operating of the courtesy lights
during the opening cycle of the gate.
CiCL
t .LUC
Timed operation (from 0 to 20 min)
no
Function disabled
CiCL
On for the entire cycle duration
AUS
Auxiliary channel
This menu allows setting the operating of the relay of the lighting of the
courtesy lights by means of a remote control stored on the channel 4 of
the receiver.
Mon
t iM
Timed operation (from 0 to 20 s)
biSt
Bistable operation
Mon
Monostable operation
SPiA
Low voltage output setup
This menu allows you to set the operation of the low voltage output.
no
no
Not used
FLSh
Flasher operation (fixed frequency)
W.L.
Indicator light operation: Indicates the status of the gate in real-time.
The type of blinking indicates the four possible conditions:
- GATE STOPPED: Light off
- GATE IN PAUSE: the light is on, fixed
- GATE OPENING: the light blinks slowly (2 Hz)
- GATE CLOSING: the light blinks quickly (4 Hz)
LP.PA
Blinker during pause time
no
no
Function deactivated
Si
Blinker will be on during the pause time too
Strt
Activation inputs (START and START P.)
This menu allows selecting input operation modes (see chapter 5.3)
StAn
StAn
Standard mode
no
Start inputs from terminal board are disabled.
Radio inputs operate in standard mode
StAn
AP.Ch
Open/Close command
PrES
Dead man operation
oroL
Timer mode
StoP
Stop Input
no
no
The input STOP is not available (ignored by the control unit)
ProS
The input STOP stops the gate: pressing the command START the gate
continues the motion
invE
The command STOP stops the gate: at the next START the gate starts
moving in the opposite direction
Содержание CITY2+L