13 - PROGRAMMING THE CONTROL UNIT
The configuration menu
-PrG
consists in a list of configurable
items; the display shows the selected item.
By pressing
i
, you will pass to the next item; by pressing
h
, you
will return to the previous item.
By pressing
OK
, you can view the current value of selected item
and possibly change it.
The last menu item (
FinE
) allows storing the carried out changes
and going back to the control unit normal operation.
You must exit from programming mode through this menu item if
you do not want to lose your configuration.
m
WARNING: in case no operation is carried out for more
than one minute, the control unit exits from the
programming mode without saving any of your setups and
changes, which will get lost.
By holding down the
i
or
h
keys, configuration menu items will
scroll fast, until item
FinE
is viewed.
In this way, you can quickly reach either the top or bottom of the
list.
P.APP
dir
FinE
-PrG
PARAMETER
VALUE
DESCRIPTION
DEFAULT
MEMO
dir
Gate direction (the direction you see from the inside)
dX
dX
The gate opens rightwards
SX
The gate opens leftwards
P.APP
Partial opening
25
0 - 1 00
The percentage of the path the gate performs in the case of opening
using the Pedestrian Start command
t.PrE
Pre-blinking time
1 .0”
0.5” - 1 ’00
Before any gate movement, blinker will be activated for
t.PrE
time, to
warn about the incoming motion (adjustable time from 0.5” to 1’00)
no
Function deactivated
t.PCh
Different closing pre-flashing time
no
0.5” - 1 ’00
If this parameter has a value assigned to it, the control unit will activate
pre-flashing prior to closure for the length of time set in this menu
(adjustable time from 0.5” to 1’00)
no
The closing pre-flashing time corresponds to
t.PrE
vEL
Speed during normal operation
18.0
3.5 - 35.0
This menu allows you to adjust gate speed during normal operation.
The value shown is in cm/s
vEL.r
Speed during slowdown
6.0
3.5 - 35.0
This menu allows you to adjust gate speed during slowdown.
The value shown is in cm/s
NOTE
: The maximum value which can be set is equal to the value set in
the menu
vEL
rAM
Starting ramp
4
0 - 6
In order not to stress too much the motor, when the motion starts the
power is gradually increased, until reached the set value or 100% if the
take-off is enabled.
Higher is the set value, longer the length of time of the ramp, that is the
time necessary to reach the value of nominal power.