ENGLISH
- 41 -
PARAMETER
VALUE
DESCRIPTION
DEFAULT
MEMO
LP.PA
Blinker during pause time
no
no
Function deactivated
Si
Blinker will be on during the pause time too
Strt
Activation inputs (START and START P.)
This menu allows selecting input operation modes (see chapter 5.3)
StAn
StAn
Standard mode
no
Start inputs from terminal board are disabled.
Radio inputs operate in standard mode
StAn
AP.Ch
Open/Close command
PrES
Dead man operation
oroL
Timer mode
StoP
Stop Input
no
no
The input STOP is not available (ignored by the control unit)
ProS
The input STOP stops the gate: pressing the command START the gate
continues the motion
invE
The command STOP stops the gate: at the next START the gate starts
moving in the opposite direction
Fot1
Photocell 1 input
This menu allows enabling the input for type 1 photocells, that is to say,
photocells active both during the opening and closing phase
no
no
Input disabled. No jumper with the common is required
AP.Ch
Input enabled
Fot2
Photocell 2 input
This menu allows enabling the input for type 2 photocells, that is to say,
photocells non active during the opening phase
CFCh
CFCh
Input enabled even at standstill gate too
no
Input disabled. No jumper with the common is required
Ch
Input enabled for the closing phase only
WARNING: if you select this option, you must disable photocell test
Ft.tE
Test of the photocells
In order to achieve a safer operation for the user, the unit performs a
photocells operational test, before a normal working cycle.
If no operational faults are found, the gate starts moving.
Otherwise, it will stand still and the flashing light will stay onfor 5 sec.
The whole test cycle lasts less than one second
no
no
Function deactivated
Si
Function activated
CoS1
Safety ribbon 1 input
This menu allows enabling the input for type 1 safety ribbon, that is to say,
fixed ribbons
no
no
Input disabled
AP
Input enabled during the opening and disabled during the closure
APCh
Input enabled in opening and closure
Содержание 12A024
Страница 2: ......
Страница 165: ...POLSKI 163 F1 L N L N F1 MAINS MAINS CITY2 CITY2 L CITY2 CITY2 L CITY2 BC OVERLOAD DOWN MENU UP BAT POW POW BAT RECEIVER...
Страница 179: ......