ENGLISH
45
45
DISPLAY
DATA
DESCRIPTION
DEFAULT
SCor
DEFAULT
AntE
MEMO
DATA
Ch.tr
Closing after passage
no
no
no
- Closing after passage disabled
0.5"÷ 20.0'
- Gate stop for a time to be set between 0.5" to 20'
Pa.tr
no/Si
Pausa dopo il transito
no
no
LP.PA
no/Si
Flashlight in pause
no
no
St.rt
Operation modes
StAn
StAn
no
- Start inputs from terminal board are disabled
StAn
- Standard operation
AP.CH
- Separated opening and closing commands
PrES
- Manned operation
oroL
- Timer operation
StoP
STOP input
no
no
no
- STOP input not available
invE
- STOP command stops the gate: START command starts
moving in the opposite direction
ProS
- STOP command stops the gate: pressing the START command
gate continues the motion
Fot 1
PHOTO 1 input
APCH
no
APCh
- Input is available for the connection of the photocell
no
- Not available
Fot 2
PHOTO 2 input
CFCh
CHCh
CFCh
- Photocell is active in closing and also when the gate is still
no
- Not available
Ch
- Photocell is active during the closing
tESt
Test of safety devices
no
no
no
- Function not active
Foto
- Test enabled only for photocells
CoSt
- Test enabled only for safety edges
Ft.Co
- Test enabled either for photocells or for safety edges
ShAd
Photocell 2 shadow zone
no
no
no
- Function disabled
F.ShA
- FOTO2 disabling higher time
i.ShA
- FOTO2 disabling lower time
CoS1
no/Si
Border 1 input (fixed border)
no
no
CoS2
no/Si
Border 2 input (mobile border)
no
no
FC.En
no/Si
End of stroke inputs
Si
no
t.inA
0 ÷ 8
Max. gate quiescent time
0
0
ASM
0.5” ÷ 3.0”
Anti-skid
0.5”
0.5”
no
- Function disabled
SEnS
0 ÷ 10
Obstacle sensor level
5
5
Cont
Counter viewing
tot
tot
tot.
- Total number of completed cycles (views in thousands or in units)
Man
- Number of cycles before the next request for service (such a number
has been rounded off to hundreds and it can be set up on 1000-step;
in case it is set up on 0, the request will be disabled and no will be viewed)
APPr
Automatic learning of the operation time
no
no
no
- Function disabled
Go
- Start up of the automatic learning procedure
FinE
End of programming
no
no
no
- It does not exit from the program menu
Si
- It exits from the program menu by storing the setup parameters
City1 FUNCTION TABLE
Содержание City1
Страница 2: ...ISTRUZIONI 1 INSTRUCTIONS 25 NOTICES 49 ANLEITUNGEN 73 INSTRUCCIONES 97 I GB F D E...
Страница 26: ...ENGLISH 48...
Страница 50: ...FRAN AIS 72...
Страница 74: ...DEUTSCH 96...