ENGLISH
34
34
Lock advance time
While the electric lock is energized, the gate will stay standstill for
t.ASE
time, to make its release easier.
In case
t.ASE
is lower than
t.SEr
, the lock energizing will go on while
the doors will start moving.
m
WARNING:
in case the gate has no electric lock, set the value 0.
Backlash time
It could be useful to give a closing command to motors, to help the
electric lock release.
The control unit controls the motors in reduced power in closing
direction for the setup time.
The backlash precedes the electric lock release. It is possible to reverse
the order by setting a lock advance time higher then the backlash one.
m
WARNING:
in case the gate has no electric lock, set the value 0.
Pre-blinking time
Before any gate movement, blinker will be activated for
t.PrE
time, to
warn about the incoming motion.
Motor 1 power
This menu allows adjusting the motor 1 power.
The displayed value is the percentage of max. motor power.
m
WARNING:
In case an hydraulic motor is used, set value 100.
Lock time
Before the opening phase begins, the control unit will energize the
electric lock in order to release it and enable the gate motion.
t.SEr
time will fix the energizing time.
m
WARNING:
in case the gate has no electric lock, set the value 0
(‘
no
’ will appear on display).