Installation instructions
CombiCooler/Cooler/WineCooler/Freezer
V6000 Supreme, integrated
1091916-R01
07/05/2020
1091916-R01
20
Completing the installation
Air circulation
A fan provides for the necessary ventilation around the condenser. In kitchens with plinths, ventilation openings must be fitted to allow
for adequate ventilation. The ventilation slits must cover
at least 50%
of the area of the plinth. It is also advisable, in this case, to re-
move the ventilation grille supplied with the appliance in order to achieve adequate ventilation. The ventilation grille is held in place with
magnetic strips and is easy to remove for regular cleaning (removing any build-up of dust). Do not block or cover the air inlets or out-
lets. Periodically dust and clean them.
SK
≥
9
2
1
8
7
Dimensions for the ventilation grille and position of the magnetic strips
C
D
E
E
A
F
B
F
G
G
L
M
M
Size system
90
60
A
894
594
B
215
C
700
400
D
200
E
about 10
F
60
G
15-30
L
Air inlet (at least 50% open)
M
Magnetic strips for holding ventilation grille
in place
Note: Maintain a distance of at least 10 mm between the plinth board and the front side of the base. Reason: Protruding screw
heads (SK)