72
Technical data
External dimensions
A
See Installation Instructions
Electrical connection
A
See identification plate
1
Note for testing institutes
The energy efficiency class according to EN 50304/EN 60350 is determined
using the
+
and
operating modes. Placing thermocouples be-
tween the appliance door and the seal can cause lack of leak tightness and
thus measuring errors.
The usable volume within the meaning of EN 50304/EN 60350 is obtained
with the shelf guides disassembled.
General note
Maximum load capacity: 3 kg
Measurement of the temperature in the cooking space
The temperature of the cooking space is measured when the cooking space
is empty according to an internationally accepted standard. Own measure-
ments may be inaccurate and are not suitable for checking the accuracy of
the temperature.
1