-2-
PARTS AND FUNCTIONS
Terminals description
Lock Control Jumper:
To set lock type
Motion Detector Connect
ion
Port:
To connect external PIR motion
detector
Main Connect
ion
Port:
To connect the bus line and the elect
ric
lock
•
L1,L2:
Connect bus line, no
-
polarity
•
PL:
External lock power input, connect to the power positive
(power +).
•
S+:
Lock power(+) output
•
S-:
Lock power(-) output, connect to the power(-) input of lock(only when
lock
is powered
from the Door Station)
1 2 3
Lock Control Jumper
PIR Motion Detector
Connect
ion
Port
+12V GND
PIR
L1 L2 PL
S+ S-
Main Connect
ion
Port
External Motion Detection
The door station is equipped with a terminal to
connect external motion detector
sensor
If the external motion detector is connected to
the system
and it
detect someone passing by
, it
will
turn on
security
light
. Additional DT-RLC is
required
12V
Motion
detector
GND
PIR