- 38 -
Ex_Meter For CT:
when using zero-export to CT mode,
the hybrid inverter can select EX_Meter For CT func�on
and use the different meters.e.g.CHNT and Eastron.
Parallel
Master
Slave
00
Modbus SN
Advanced Function
Paral.
Set3
EX_Meter For CT
Meter Select
0/3
No Meter
CHNT
Eastron
6. Mode
5.11 Device Info Setup Menu
Mode I:Basic
HMI:
LCD version
Volt
1
2
3
50.38V 19.70A 30.6C
52.0%
26.0Ah 0.0V
0.0A
0|0|0
50.33V 19.10A 31.0C
51.0%
25.5Ah 53.2V 25.0A 0|0|0
50.30V 16.90A 30.2C
12.0%
6.0Ah
53.2V 25.0A 0|0|0
4
5
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
6
7
8
9
10
11
12
13
14
15
Curr
Volt
Curr
Temp
SOC
Energy
Charge
Fault
Sum
Data
Details
Data
Li-BMS
Volt
1
2
3
50.38V 19.70A 30.6C
52.0%
26.0Ah 0.0V
0.0A
0|0|0
50.33V 19.10A 31.0C
51.0%
25.5Ah 53.2V 25.0A 0|0|0
50.30V 16.90A 30.2C
12.0%
6.0Ah
53.2V 25.0A 0|0|0
4
5
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V 0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
6
7
8
9
10
11
12
13
14
15
Curr
Volt
Curr
Temp
SOC
Energy
Charge
Fault
Sum
Data
Details
Data
Li-BMS
Device Info.
Inverter ID: 2102199870 Flash
MAIN:Ver2002-1046-1707
SUN-12K
HMI: Ver 1001-8010
Alarms Code
F13 Grid_Mode_changed
F13 Grid_Mode_changed
F56 DC_VoltLow_Fault
F23 Tz_GFCI_OC_Fault
2021-06-11 13:17
2021-06-11 08:23
2021-06-11 08:21
2021-06-10 13:05
Occurred
Device
Info
MAIN:
Control board FW version
This page show Inverter ID, Inverter version and alarm
codes.
Grid
Backup Load
On-Grid Home Load
CT
Battery
Solar
AC cable
DC cable
COM cable
This is for Wind Turbine
16.5
0
310
I/A
U/V
DC 1 for WindTurbine
V1
V2
V3
V4
V5
V6
V7
V8
V9
V10
V11
V12
90V
110V
130V
150V
170V
190V
0.0A
1.5A
3.0A
4.5A
6.0A
7.5A
210V
230V
250V
270V
290V
310V
9.0A
10.5A
12.0A
13.5A
15.0A
16.5A
DC 2 for WindTurbine
Advanced Function
Wind
Set2