page
Level limit switch
Series RF 8000
Technical Information / Instruction manual
Electrical installation
Electronic module: Standard
(Relay SPDT / Solid State)
Note: Switch and potentiometer settings are for illustration purposes only.
re
d
b
la
ck
wh
ite
Connect protective earth wire to terminal provided in housing and marked with
1. Loosen the lid clip and remove the lid to access the connectors and electronics.
2. Connect the wires to the terminals
3. Ground the instrument according to local regulations.
4. Tighten the gland to form a good seal.
Power supply:
12 to 250 V AC/DC (0 to 60 Hz)
2W max.
Signal output:
Relay:
Floating relay SPDT
AC max. 250V, 8A, 2000VA, non inductive
DC max. 30V, 5A, 150W, non inductive
Solid state switch:
30 V DC or 30 V AC (peak), 82 mA
Observe protection (see below)
Power
supply
Relay
internal
wiring
Solid state switch
(polarity not important)
Protection diode
Observe a Protection diode in case of
connecting an external relay to the Solid
state switch
Protection of Solid State Switch
Solid
state
switch
internal
wiring
1
2
3
4
5
6
7
8
9
10
11
12
RF 8000 c
gi150917
21