Connecting to power supply
page 24
Fig. 18: Connection steps 5 and 6
6. Insert the wire ends into the terminals according to the bottom
wiring plan
Note:
Fixed conductors and flexible conductors with ferrules can be
inserted directly into the terminal openings. In the case of flexible
conductors for opening the terminals, use a screwdriver (3 mm
blade width) to push the actuator lever away from the terminal
opening. When released, the terminals are closed again.
7. Check the hold of the wires in the terminals by lightly pulling on
them
8. Tighten the compression nut of the cable entry gland. The seal
ring must completely encircle the cable
9. Reinsert the display and adjustment module, if one was installed
10. Screw the housing lid back on
The electrical connection is finished.